Optional presentation practice. Choices and model launches do not write LMS grades, completion or certificates. This extension takes additional learning time.
1. Respiratory protection and face-fit awareness Match the wearer, facepiece and exposure controls before relying on RPE.
2. Choose a learning route 3. Trace contaminated air to the wearer Trace contaminated air to the wearer.
Tight-fitting respiratory protective equipment depends on a seal against the individual face. Contaminated air can pass around a poor seal instead of through the intended protection. Movement, speech, stubble or incompatible eye protection can disturb that seal.
Tight-fitting respiratory protective equipment depends on a seal against the individual face. Contaminated air can pass around a poor seal instead of through the intended protection. Movement, speech, stubble or incompatible eye protection can disturb that seal. Harm depends on the substance: irritation may occur quickly, while repeated exposure can contribute to asthma, lung disease or cancer much later. Feeling well during a task does not demonstrate adequate control.
A fit test checks the selected facepiece on a particular wearer. It does not measure workplace exposure or approve the complete task. Start with the actual material and airborne source, people nearby and the assessed controls. Ask what the evidence covers before treating a pass as permission to work.
4. The fictional case and decision boundary Trace contaminated air to the wearer.
Task and setting A maintenance team prepares a dusty task. Its normal facepiece is unavailable, new eye protection has arrived, and the supervisor must reconcile the equipment with individual fit evidence. Decision to practise Extraction has failed during a dusty repair. The store has enough masks for the main operators, so the team proposes continuing while cleaners work nearby. Evidence to consider Control the source before relying on PPE.
5. Decision 1: interpret the evidence Extraction has failed during a dusty repair. The store has enough masks for the main operators, so the team proposes continuing while cleaners work nearby.
Which response follows the hierarchy?
Stop the affected task and restore or review the required source controls. (supported response) Continue because issuing masks restores extraction. Give only the cleaners a warning and carry on. PPE does not restore a failed engineering function or establish protection of people around the task.
6. Reconsider the evidence Which response follows the hierarchy?
Stop the affected task and restore or review the required source controls. (supported response) Continue because issuing masks restores extraction. Give only the cleaners a warning and carry on. PPE does not restore a failed engineering function or establish protection of people around the task.
7. Decision 1 explained PPE does not restore a failed engineering function or establish protection of people around the task.
Control the source before relying on PPE.
8. Control the source before relying on PPE Control the source before relying on PPE.
PPE protects the person against remaining risk; it does not remove the source. Before selecting a mask, consider avoiding the exposure-producing work, a genuinely safer material or method, and effective enclosure or extraction. Procedures and access arrangements support those controls.
PPE protects the person against remaining risk; it does not remove the source. Before selecting a mask, consider avoiding the exposure-producing work, a genuinely safer material or method, and effective enclosure or extraction. Procedures and access arrangements support those controls. RPE may still be needed for residual exposure, but issuing it cannot make a failed engineering control acceptable. Nearby workers and cleaners may remain exposed even when the operator wears a mask.
Judge the whole arrangement during the real task. Check that the assessed source controls are available and being used as intended. If they fail, stop the affected activity safely and obtain review. Counting issued masks is weaker evidence than observing effective capture and correct, compatible equipment use.
9. Match the protection question Match each card to its meaning. Drag, or use the labelled category selector.
Match each card to its meaning. Drag, or use the labelled category selector.
Does the filter suit the actual contaminant? — Task and selection. Selection must match the exposure. Does this model and size fit this wearer? — Individual seal. Fit testing addresses the selected seal. Is the issued item undamaged and checked before use? — Present readiness. This is a current user check. 10. Compare the reasoning: Match the protection question Does the filter suit the actual contaminant? Task and selection Does this model and size fit this wearer? Individual seal Is the issued item undamaged and checked before use? Present readiness
Match each card to its meaning. Drag, or use the labelled category selector.
Does the filter suit the actual contaminant? — Task and selection. Selection must match the exposure. Does this model and size fit this wearer? — Individual seal. Fit testing addresses the selected seal. Is the issued item undamaged and checked before use? — Present readiness. This is a current user check. 11. Separate suitable protection from a good fit Separate suitable protection from a good fit.
Selection starts with the substance, its form, exposure conditions and the task. A facepiece must provide the assessed protection and be suitable for the wearer, work and other PPE. A good seal cannot make an unsuitable filter protect against a different contaminant.
Selection starts with the substance, its form, exposure conditions and the task. A facepiece must provide the assessed protection and be suitable for the wearer, work and other PPE. A good seal cannot make an unsuitable filter protect against a different contaminant. A particle-filter classification does not establish protection against a gas or vapour. Filtering RPE is unsuitable for oxygen-deficient atmospheres; an awareness learner must not improvise specialist respiratory equipment or entry arrangements.
Use the competent assessment and manufacturer information rather than choosing from a photograph or familiar label. Resolve missing substance or selection information before exposure. The employer should also address whether the person can use the selected equipment safely, with confidential medical advice where needed, without sharing unnecessary health details.
12. Decision 2: choose the response The store issues the same filter class in a different mask size. The record names the original size, and the worker has not been tested in the replacement.
What should the supervisor do?
Alter the record to match the box. Hold the substitution pending matching equipment or competent review and fit testing. (supported response) Accept any size with the same filter class. The actual facepiece must match the wearer-specific evidence; changing a record cannot create a seal result.
13. Compare the consequences What should the supervisor do?
Alter the record to match the box. Hold the substitution pending matching equipment or competent review and fit testing. (supported response) Accept any size with the same filter class. The actual facepiece must match the wearer-specific evidence; changing a record cannot create a seal result.
14. Decision 2 explained The actual facepiece must match the wearer-specific evidence; changing a record cannot create a seal result.
Match the issued facepiece to its evidence.
15. Match the issued facepiece to its evidence Match the issued facepiece to its evidence.
A usable fit-test record identifies the wearer and the facepiece tested, including its type, make, model and size. Relevant equipment and other PPE information help the supervisor confirm what can actually be issued.
A usable fit-test record identifies the wearer and the facepiece tested, including its type, make, model and size. Relevant equipment and other PPE information help the supervisor confirm what can actually be issued. A certificate stating only a broad filter class does not establish that another brand or size fits the individual. The controlled record must be available to the people who need to check it without exposing unrelated clinical information.
Compare the physical item with the record before use. Procurement substitutions and new head-worn PPE can change the arrangement. Obtain the tested equipment or a competent selection and fit review for an alternative. Do not turn stock pressure or a generic certificate into evidence that a replacement is suitable.
16. Sort the evidence Sort the cards. Drag each card, or use its labelled category selector.
Sort the cards. Drag each card, or use its labelled category selector.
Exact wearer and facepiece identified in the report. — Supports the stated check. The evidence can be matched to the issued item. Same filter class on an untested replacement size. — Does not establish acceptance. Classification does not establish individual fit. Extraction failure treated as a reason to pause. — Supports the stated check. A failed source control needs action. A certificate used to approve an unknown coating. — Does not establish acceptance. The material question remains unresolved. 17. Compare the reasoning: Sort the evidence Exact wearer and facepiece identified in the report. Supports the stated check Same filter class on an untested replacement size. Does not establish acceptance Extraction failure treated as a reason to pause. Supports the stated check A certificate used to approve an unknown coating. Does not establish acceptance
Sort the cards. Drag each card, or use its labelled category selector.
Exact wearer and facepiece identified in the report. — Supports the stated check. The evidence can be matched to the issued item. Same filter class on an untested replacement size. — Does not establish acceptance. Classification does not establish individual fit. Extraction failure treated as a reason to pause. — Supports the stated check. A failed source control needs action. A certificate used to approve an unknown coating. — Does not establish acceptance. The material question remains unresolved. 18. Use the wearer check every time Use the wearer check every time.
Fit testing and a wearer seal check serve different purposes. The fit test assesses the selected tight-fitting facepiece; the seal check helps identify immediate problems each time it is put on.
Fit testing and a wearer seal check serve different purposes. The fit test assesses the selected tight-fitting facepiece; the seal check helps identify immediate problems each time it is put on. Follow the manufacturer instructions in a safe area, inspect the equipment, check seal-area hair and add compatible PPE. A generic pressure manoeuvre may not suit every design. Neither a quick check nor a colleague saying it looks right replaces the fit test.
During exposure, keep the protection in position. If it slips, leaks, becomes damaged, breathing becomes difficult or the wearer feels unwell, leave by the planned safe route and report the problem. Do not lift the facepiece to speak or attempt a repair inside the contaminated area.
19. Decision 3: apply and review A wearer reports changed fit after dental work while the recorded review date is months away. The supervisor must decide whether the unchanged diary entry is sufficient.
What should trigger action?
Only arrival of the planned review date. A decision by the wearer to accept the leak. The reported change and doubt about fit, regardless of the future diary date. (supported response) Changed circumstances can require review before a scheduled date; unresolved fit must not be accepted as protection.
20. Revisit the control or support boundary What should trigger action?
Only arrival of the planned review date. A decision by the wearer to accept the leak. The reported change and doubt about fit, regardless of the future diary date. (supported response) Changed circumstances can require review before a scheduled date; unresolved fit must not be accepted as protection.
21. Decision 3 explained Changed circumstances can require review before a scheduled date; unresolved fit must not be accepted as protection.
Report changes and verify safe return.
22. Report changes and verify safe return Report changes and verify safe return.
Fit evidence needs review when the facepiece changes, the wearer changes physically or there is reason to doubt fit. Relevant changes can include facial injury, dental changes, weight change or new head-worn PPE. There is no universal expiry interval that settles every case.
Fit evidence needs review when the facepiece changes, the wearer changes physically or there is reason to doubt fit. Relevant changes can include facial injury, dental changes, weight change or new head-worn PPE. There is no universal expiry interval that settles every case. The RPE programme should set a risk-based review arrangement and respond to changes before a diary date where necessary. Users should know how to report discomfort, defects and unavailable stock.
After use, follow contamination-control arrangements, clean and store reusable equipment as instructed, dispose of single-use items correctly and keep defects out of circulation. Restart follows confirmation that task controls, selection, fit and equipment condition are restored. A new appointment booking alone does not make an unresolved exposure task ready.
23. Choose the return-to-task conditions Choose every supported action. Leave the unsuitable actions unselected.
Choose every supported action. Leave the unsuitable actions unselected.
Required source controls are restored and verified. — Supported action. RPE does not replace failed extraction. Equipment and fit evidence match the wearer and task. — Supported action. Resolve the actual protection chain. The next fit-test appointment is booked, so any mask may be used. — Leave unselected. Booking does not establish current protection. Defective equipment is returned to general stock. — Leave unselected. Keep defects out of circulation. 24. Compare the reasoning: Choose the return-to-task conditions Required source controls are restored and verified. Supported action Equipment and fit evidence match the wearer and task. Supported action The next fit-test appointment is booked, so any mask may be used. Leave unselected Defective equipment is returned to general stock. Leave unselected
Choose every supported action. Leave the unsuitable actions unselected.
Required source controls are restored and verified. — Supported action. RPE does not replace failed extraction. Equipment and fit evidence match the wearer and task. — Supported action. Resolve the actual protection chain. The next fit-test appointment is booked, so any mask may be used. — Leave unselected. Booking does not establish current protection. Defective equipment is returned to general stock. — Leave unselected. Keep defects out of circulation. 25. Apply the lesson in a fictional workplace A maintenance team prepares a dusty task. Its normal facepiece is unavailable, new eye protection has arrived, and the supervisor must reconcile the equipment with individual fit evidence.
Report changes and verify safe return.
26. Take the learning into a fictional task Report changes and verify safe return.
Task and people A maintenance team prepares a dusty task. Its normal facepiece is unavailable, new eye protection has arrived, and the supervisor must reconcile the equipment with individual fit evidence. Control or support Match the issued facepiece to its evidence. Check and review Report changes and verify safe return.
27. Explain your reasoning without the answer sheet Use the supplied case facts. Explain why a choice fits the task and what remains uncertain. A points total or completed form cannot replace the required control or support arrangement.
28. Continue with the full course and Knowledge Hub Use the original course for its six lessons, required activities, final assessment and saved record. This optional companion does not change course grades, completion or certificates.
Enable JavaScript for interactive practice, or use the PowerPoint and its notes.