APPLY THE LEARNING

Workplace practice sheets

Use the fictional evidence in your own notes. The exercises do not create or approve operational records.

LEV observation and defect sheet

For the workshop case, identify the source, hood, working position, user indicator, visible defects and stop point. State who verifies capture after repair without inventing an airflow value.

  1. Fictional exercise: A workshop uses extraction during sanding and bench work. The fan is audible, but the work position has changed and dust appears outside the expected capture area.
  2. For the workshop case, identify the source, hood, working position, user indicator, visible defects and stop point. State who verifies capture after repair without inventing an airflow value.
  3. Make three columns: observed facts, missing evidence and the responsible action. State the condition that prevents starting or requires stopping, and the verification needed before release. Do not invent results or approvals.

Open the live SHAREhub resource ↗

Optional extension. Live SHAREhub tools may need a separate sign-in. The included exercise works offline and submits no workplace record.

Optional visual practice and worked application

Use these fictional exercises to compare evidence and rehearse decisions. They do not alter course completion or assessment requirements. You can work through the same choices on paper.

Follow contamination through the complete LEV chain

Fictional continuing case. The supervisor’s check asks only whether extraction exists and the motor runs. No record confirms capture for the new work position.

Capture is the purpose

LEV must intercept the contaminant for the actual task before it reaches breathing zones. A system’s presence or fan sound is not evidence that the required capture works.

A connected system

Hood, duct, air cleaner, fan and discharge work together. A change to a shared branch can affect demand and capture elsewhere; the discharge route can also create re-entry exposure.

Worked user-check question

Identify the specified system indicators and the task position from the established arrangements. Record the mismatch: the operator is outside the assessed working zone. Refer the changed duty for competent review rather than extending an old station result everywhere.

Match the LEV observation to its question

Fictional worked application: A fictional fabrication shop adds a new extraction branch after a duct repair. The fan sounds normal and the central indicator is acceptable. One operator’s work is now outside the assessed capture position, and the proposed discharge could return through an opening. Stage evidence: The supervisor’s check asks only whether extraction exists and the motor runs. No record confirms capture for the new work position.

Match the LEV observation to its question. Use the evidence in this stage, rather than assuming what happened off screen.

  • The source is outside the established capture position. Task capture. The old station result does not accept this new position.
  • Another branch is connected to the shared system. Whole-system demand. Changed demand can affect required capture at other stations.
  • Extracted air may enter an occupied opening. Discharge/re-entry. The full contaminant route includes discharge and possible re-entry.

Open this interactive lesson

Record an LEV user defect and verification route

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Use only a fictional or authorised non-confidential example. Keep planned actions separate from verified current protection.

A saved practice entry does not alter the graded course or authorise work.

Separate user condition, functional duty and examination

Fictional continuing case. A replacement filter is fitted. The maintenance report has no required functional verification, and an examination report contains a critical unresolved defect.

Different evidence questions

A user check concerns stated readiness and use conditions. Functional evidence concerns control performance for the assessed duty. A competent examination has its own scope and findings; filing any one record does not answer every question.

Work created by maintenance

Opening a contaminated collector can create exposure even after the fan stops. Cleaning and maintenance require suitable assessed arrangements rather than ordinary housekeeping assumptions.

Worked defect entry

Record the affected system/station, defect and relevant restriction. Identify required corrective work, verification and responsible acceptance. A new filter or current-year folder is not the complete control-restoration evidence.

Choose evidence that addresses the unresolved LEV duty

Fictional worked application: A fictional fabrication shop adds a new extraction branch after a duct repair. The fan sounds normal and the central indicator is acceptable. One operator’s work is now outside the assessed capture position, and the proposed discharge could return through an opening. Stage evidence: A replacement filter is fitted. The maintenance report has no required functional verification, and an examination report contains a critical unresolved defect.

Choose evidence that addresses the unresolved LEV duty. Select every defensible evidence or action; leave unsupported substitutes unselected.

  • Required functional performance checks for the complete affected system and task positions. Relevant evidence. The new filter alone does not demonstrate capture.
  • Corrective work and responsible acceptance resolving the examination defect. Relevant evidence. The critical finding remains open until its required response is evidenced.
  • Fan noise used as the only evidence that the whole system protects all stations. Insufficient evidence. Motor operation is not the same as effective task capture.
  • Opening the collector as routine cleaning because the fan is stopped. Insufficient evidence. Stopped airflow does not remove contamination or maintenance-task exposure.

Open this interactive lesson

Record an LEV user defect and verification route

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Use only a fictional or authorised non-confidential example. Keep planned actions separate from verified current protection.

A saved practice entry does not alter the graded course or authorise work.

Accept the restored duty within its tested scope

Fictional continuing case. Production has stopped and someone proposes immediate enclosure entry. The established clearance condition has not been satisfied.

Use the established clearance

Stopping the source is not automatically an all-clear. Follow the verified clearance and protective arrangements rather than decide from visibility.

Review changes before reliance

A new material or vapour may fall outside the collector’s specified duty. Competent review of actual material, suitability and use is needed; a clean exterior does not establish suitability.

Close the right question

The relevant performance must be verified with responsible acceptance. Record which station, operating combination and duty were checked, and retain the change trigger for new branches or tasks.

Follow the repaired system to safe reliance

Fictional worked application: A fictional fabrication shop adds a new extraction branch after a duct repair. The fan sounds normal and the central indicator is acceptable. One operator’s work is now outside the assessed capture position, and the proposed discharge could return through an opening. Stage evidence: Production has stopped and someone proposes immediate enclosure entry. The established clearance condition has not been satisfied.

Has the critical defect and changed capture duty been resolved through the responsible competent route?

  • Has the critical defect and changed capture duty been resolved through the responsible competent route?
    • No / not established in this case: A running motor and fitted filter do not settle the task-capture gap. Next: Current decision — Retain the affected restriction and obtain the missing corrective/performance evidence.
    • Yes, supported by the stated evidence: Proceed to the separate verification question; the first condition alone is not the final decision. Next: Are the established clearance and protective conditions satisfied for the proposed entry?
  • Current decision

    Retain the affected restriction and obtain the missing corrective/performance evidence.

  • Are the established clearance and protective conditions satisfied for the proposed entry?
    • The relevant evidence is still missing: Keep the entry/release question open until the required conditions are verified. Next: Verification still required — Keep the entry/release question open until the required conditions are verified.
    • Yes, the responsible check is evidenced within its scope: Record the accepted scoped conditions and communicate the current limits. Next: Scoped decision supported — Record the accepted scoped conditions and communicate the current limits.
  • Verification still required

    Keep the entry/release question open until the required conditions are verified.

  • Scoped decision supported

    Record the accepted scoped conditions and communicate the current limits.

Open this interactive lesson

Record an LEV user defect and verification route

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Draw the hood-to-discharge chain. At each connection write the supplied observation, what it actually proves and the separate competent evidence needed. Include the work position and re-entry route.

Use only a fictional or authorised non-confidential example. Keep planned actions separate from verified current protection.

A saved practice entry does not alter the graded course or authorise work.

Optional choices save on this browser, separately from recorded course progress. Live tools retain their own access and competent-review requirements.