SHARE Knowledge Hub
Electric shock and electrocution injuries
Electrical injury can follow body contact with current, an arc, an electrical fire or a secondary fall. A small visible burn does not tell the whole injury story, and a casualty still connected to electricity also endangers rescuers. Make the scene safe first, summon emergency help, use trained first aid, and keep the event under competent investigation before equipment returns to use.
Understanding Electric shock and electrocution injuries
Electrocution means death caused by electric current. Electrical injury is broader: it includes electric shock, electrical burns, thermal burns, arc injury, blast effects and secondary trauma such as a fall or impact with machinery. Electrical current can cause deep burns and affect heart or breathing function; the clinical severity cannot be established from a workplace visual check. Employers must treat electrical injury as a potentially serious outcome and prevent the exposure pathway rather than judging severity only by the equipment, the visible injury or whether a circuit tripped. Sources: HSE injury mechanisms.
Why this matters at work
Use the terms accurately. Electrocution is a fatal electric-current injury. Electric shock means current passes through the body and can be minor or life-threatening. Electrical burns arise when current heats tissue along the path; thermal burns arise from hot equipment, fire or arc heat. Arc injury can occur without direct touch, and an electrical event can cause a person to fall, be thrown, lose control of machinery or be exposed to fire, smoke or explosion. HSE distinguishes short static discharges in ordinary carpet/car scenarios from sustained current exposure; static can still ignite an explosive atmosphere or startle a person into secondary injury. Do not classify an unexplained equipment shock as harmless static. Sources: HSE injury distinctions.
Direct contact is not the only pathway. A fault may energise metalwork that should be safe to touch. Damaged insulation, wet equipment, defective plugs/connectors, exposed conductors, incorrect repairs, failed earthing/protection, poor isolation, backfeed and unsafe testing can all create a current path. Arcing can cause injury without the person holding a conductor. The prevention question is what allowed energy and a person to meet, not whether the final movement looked careless.
How organisations manage this in practice
Process failure: Minor shocks and near misses are normalised | How control is lost: Underlying defects and workarounds accumulate until severe event | Possible consequence: Electrocution, burns, repeat incidents and weak reporting culture | Management measures assurance and recovery: Avoid: reject unsafe workaround; Limit scope: reduce pressure/exposure; Restrict release: quarantine defects; Management arrangements: fair reporting, prompt repair, root-cause review and leadership assurance; Residual task protection: residual PPE; Implementation assurance: manager checks reports produce prompt restriction, funded corrective action and fair follow-up with affected workers.
Injury prevention begins with safe system design and selection. Electrical installations and equipment must be suitable for intended use and conditions, protected from damage, sufficiently robust, correctly maintained and accessible for safe isolation and emergency action. Consider supply, load, environment, water, dust, heat, chemicals, traffic, public access, cable route, mechanical stress, cleaning, work position, ignition risk and the effect of failure on safety functions. Use a competent person to design, install, assess and modify electrical systems.
Useful leading indicators include damaged cables/connectors, hot equipment, burn marks, unplanned trips, repeated reset, unavailable isolation points, missing covers, water ingress, overdue inspection/maintenance, incomplete permits, unclear asset identity, temporary supplies, vehicle impact, worker reports, near misses, contractor findings and emergency-drill weaknesses. Review by asset, task, location, shift and consequence. Low injury numbers do not prove that electrical barriers work if reporting or exposure is low.
Protect the rescuer before approaching a shocked person
At the scaffold incident, the response includes possible fall injury as well as electrical injury. Keep rescuers and others outside the electrical danger and use the site emergency arrangements. Trained responders and clinicians determine care; feeling well or a small visible burn cannot clear a person for work.
- Immediate safe response — Avoid contact with a live source; summon emergency help and trained first aid.
- Arc burns or a secondary fall — Use clinical assessment; visible injury alone cannot establish severity.
- Prevent another exposure — Secure the affected supply and equipment for competent investigation.
The supervisor quarantines the affected supply and access as well as the damaged lead. A competent electrical owner checks the fault, protective system and surrounding work before controlled return. Clinical assessment and equipment restart are separate decisions.
Content amended 19 October 2026 by the SHARE Knowledge Hub editorial team. This records an editorial content change; the existing technical-review and approval status still applies.
Protect the witness before approaching the casualty
A person or object may remain connected to electricity. Emergency assistance and competent source control must not expose a second person to the same hazard.

Do not let an electrical incident create a second casualty

Full written explanation
Inert construction exercise: a training mannequin and closed cabinet illustrate the access question, not a live rescue.
- Treat source status as unknown. A stopped tool or closed cabinet does not prove that electricity or retained energy has been controlled. Keep others clear of the hazard.
- Protect the witness. Do not touch a person or object that may remain connected to live electricity. Arrange competent source control and safe access.
- Get emergency assistance. Use the emergency call and site arrangements without waiting for records. Trained care follows when access is safe.
Change the pathway
- An exercise is not a result. No energised conductor or verified isolation is shown in this scene.
- No improvised rescue. The illustration provides no switching, testing or rescue technique.
- Keep care and records distinct. A small mark or apparent recovery cannot determine injury severity.
Evidence check: Use current HSE/NHS guidance and the full topic. No live rescue, switching, test method, clinical treatment sequence or safe voltage is supplied.
Witness protection, competent source control and the existing emergency/medical route
Primary references: HSE: electrical injury mechanisms (GB) · HSE: first-aid questions and electric-shock guidance (GB) · NHS: burns and scalds, including electrical burns
Open the complete HD image (new tab)Download image
Witness protection, competent source control and the existing emergency/medical route
Primary references: HSE: electrical injury mechanisms (GB) · HSE: first-aid questions and electric-shock guidance (GB) · NHS: burns and scalds, including electrical burns

Do not create another casualty
Keep clear of the electrical source and use the appropriate emergency call and site arrangements.
Competent control
Arrange suitable source control and confirmation of safe access; do not assume the supply or stored energy has been removed.
Care and evidence
Provide appropriate first aid when safe, obtain medical assistance and keep affected equipment out of use pending investigation and competent verification.
This overview is not a live rescue, switching or clinical treatment procedure.
What is the health and advice boundary for electrocution injuries?
This page is workplace guidance for prevention, response and learning; it is not medical, legal or HR advice.
What is the health and advice boundary for electrocution injuries?
Read the complete visual as text
- This page is workplace guidance for prevention, response and…: This page is workplace guidance for prevention, response and learning; it is not medical, legal or HR advice.
- Suspected significant electric shock, electrical burn, loss of consciousness,…: Suspected significant electric shock, electrical burn, loss of consciousness, breathing difficulty, chest symptoms, fall from height, arc-flash exposure or contact with high-voltage equipment requires medical assessment. Workers should not be asked to self-diagnose whether a shock was harmless, because some effects may not be obvious at the workface.
- The workplace role is to make the area safe,…: The workplace role is to make the area safe, isolate the energy source if safe, protect rescuers, provide first aid within competence, arrange medical support, report and investigate the event, and prevent recurrence.
Suspected significant electric shock, electrical burn, loss of consciousness, breathing difficulty, chest symptoms, fall from height, arc-flash exposure or contact with high-voltage equipment requires medical assessment. Workers should not be asked to self-diagnose whether a shock was harmless, because some effects may not be obvious at the workface.
The workplace role is to make the area safe, isolate the energy source if safe, protect rescuers, provide first aid within competence, arrange medical support, report and investigate the event, and prevent recurrence.
What are the key facts about electrocution injuries?
The key facts are that electrical injury can be fatal, externally subtle, delayed in effect and often preventable through planned controls.
Do not touch an energised casualty
The first responder can become the second casualty if the electrical supply has not been isolated.
Shock can affect heart and breathing
Current through the body can disrupt normal electrical signalling and muscle control.
Burns may be deep
Entry and exit marks can underestimate the internal injury caused by current flow or arc energy.
Falls and secondary trauma are common
A shock can throw a person, cause a fall or pull them into machinery or structures.
Wet conditions make injury more likely
Moisture and conductive surfaces can reduce resistance and increase current flow.
Every shock is learning information
Even a minor shock or near miss should trigger action before the same weakness injures someone more severely.
What is the first safe decision after electric shock?
Keep rescuers out of contact, isolate the electrical source if safe, and call emergency services. Only approach once the electrical hazard is controlled.
A witness should not pull a colleague off an energised conductor with bare hands. A trained first aider can assess breathing and provide care after the scene is safe; diagnosis, monitoring and return-to-work decisions belong to clinical professionals.
Who decides medical follow-up and return to work?
Clinical professionals decide assessment, treatment and fitness; the employer controls the electrical hazard and work arrangements.
What are electrocution injuries?
Electrocution injuries are injuries caused by electrical energy acting on the body or by the secondary consequences of electrical contact.
The term covers fatal electrocution, non-fatal electric shock, electrical burns, arc-flash burns, thermal burns, loss of muscle control, breathing effects, cardiac rhythm disturbance, falls, collisions and blast-related trauma. A person may be injured by touching live parts, by equipment becoming live through a fault, by an electrical explosion, or by being near high-voltage energy.
The workplace focus is not diagnosis; it is prevention and control. A strong investigation asks how the energy reached the person, why barriers did not prevent it, whether the environment made it worse, and what evidence existed before the incident that risk was drifting.
| Aspect | Meaning | Workplace relevance |
|---|---|---|
| Electric shock | Current passes through the body. | Can affect heart, breathing and muscle control. |
| Electrocution | Commonly used for fatal electric shock. | Represents failure of electrical risk controls. |
| Electrical burn | Current or arc energy damages tissue. | May need medical assessment even if small. |
| Arc-flash injury | Fault energy releases heat, light and pressure. | Can occur without direct conductor contact. |
| Secondary trauma | Shock causes fall, impact or machinery contact. | Requires task-location planning. |
What immediate workplace actions matter after suspected electric shock?
The immediate workplace priority is to protect rescuers, break contact with the electrical source and arrange suitable first aid and medical assessment.
People must not touch a casualty who may still be in contact with live electricity. The supply should be switched off or isolated where it is safe to do so. If isolation is not possible, the area should be kept clear and emergency services contacted. After the person is no longer energised, first aiders should follow their training and site emergency arrangements.
Burns should be cooled using appropriate first-aid principles and covered as guided by first-aid training. The incident area should be preserved once people are safe, because cable condition, switch positions, equipment defects, PPE, permits, test instruments and environmental conditions may all be important evidence.
| Step | What to do | Why it matters |
|---|---|---|
| Make responders safe | Do not touch the person until the source is isolated or confirmed safe. | Prevents a second casualty. |
| Stop the energy | Switch off, isolate or keep people away until competent help arrives. | Breaks the contact pathway. |
| Give first aid within competence | Follow first-aid training for breathing, burns and injuries. | Provides immediate support without improvisation. |
| Arrange medical assessment | Escalate significant shocks, burns, collapse, chest symptoms, high-voltage or arc exposure. | Effects may be serious or delayed. |
| Secure the area | Prevent reuse of equipment or re-energisation. | Stops recurrence before investigation. |
| Report and investigate | Record what happened and preserve evidence. | Finds causes beyond individual behaviour. |
HSE’s first-aid guidance routes electric-shock first aid to trained responders. Make the electrical source safe and call emergency services before anyone approaches an exposed live hazard. HSE first-aid FAQs: electric shock (official source).
How does electrical current injure the body?
Electrical current injures the body by interfering with normal electrical signalling, heating tissue and causing involuntary muscle contraction.
Electrical contact, heat and secondary harm are different pathways

Full written explanation
A conceptual relationship map shows contact current branching to disruption of normal heart, breathing or muscle signals and to tissue heating. A separate arc/thermal branch leads to burns, blast or secondary impact; this need not involve contact current passing through the person. The bottom response band keeps witnesses clear, emergency assistance prompt, and trained care conditional on safe access. It is not a diagnosis, severity scale or live-rescue procedure.
Industrial-workshop comparison: understand possible harm while the existing response and normal anatomy remain separate.
- Keep people clear of the source. A casualty or object may still be energised. Competent source control and confirmation of safe access remain essential.
- Arrange emergency help. Use the site emergency call and assistance route promptly; an exercise or incident log is not a care gate.
- Give care when access is safe. Follow first-aid training and obtain appropriate medical assessment. Electrical burns require emergency medical assessment.
- Hold equipment and learn later. Once people are protected, prevent reuse and retain relevant circumstances for competent investigation and verification.
When the evidence does not fit: Do not infer severity from a skin mark or apparent recovery. An electrical burn needs emergency medical assessment; a workplace photograph cannot clear a person or equipment.
Who acts: Site emergency/first-aid roles, competent electrical support and medical responders under the actual arrangements.
Changed workplace
Construction exercise: Keep witnesses clear and use the emergency route while source status is unresolved.
Industrial workshop: Separate current, heat/arc and secondary harm; retain the normal anatomy explainer.
Evidence check: Use current HSE/NHS guidance and the full topic. No live rescue, switching, test method, clinical treatment sequence or safe voltage is supplied.
Witness protection, competent source control and the existing emergency/medical route
Primary references: HSE: electrical injury mechanisms (GB) · HSE: first-aid questions and electric-shock guidance (GB) · NHS: burns and scalds, including electrical burns
Open the complete HD image (new tab)Download image
Witness protection, competent source control and the existing emergency/medical route
Primary references: HSE: electrical injury mechanisms (GB) · HSE: first-aid questions and electric-shock guidance (GB) · NHS: burns and scalds, including electrical burns
The body relies on electrical signals for heart rhythm, breathing and muscle movement. External electrical current can disrupt those signals. Current crossing the chest is particularly concerning because it may affect the heart. Current can also trigger painful muscle contraction, preventing the person from letting go and increasing contact time.
Heat is another mechanism. Electrical energy can heat tissue internally and externally. Arc flash adds intense radiant heat, pressure, light and molten metal. This is why an electrical injury can be more serious than the first visible mark suggests.
| Mechanism | What happens | Workplace example |
|---|---|---|
| Cardiac rhythm disturbance | Current interferes with heart electrical activity. | Hand-to-hand shock across chest. |
| Respiratory effect | Shock affects breathing control or muscles. | Person collapses after contact. |
| Muscle tetany | Muscles contract and person cannot let go. | Grip on live tool or conductor. |
| Deep burn | Current heats tissue along the pathway. | Entry/exit burns from contact. |
| Arc-flash burn | Fault energy causes severe thermal injury. | Panel fault during testing. |
| Blast/secondary injury | Pressure or startle causes falls and impact. | Worker thrown from ladder. |
Current may disrupt the heart, breathing and muscle control, while electrical and thermal burns can damage tissue. A fall or arc blast can add trauma even without current passing through the body. Record the exposure circumstances for clinical and incident follow-up rather than inferring severity from a skin mark. See HSE injuries.

How can electricity injure the body, and why can a small mark hide a serious incident?
Interactive anatomy · Electrical injury · Updated 2026-10-23
Electrical injury terms
A broad term for injury associated with electrical exposure.
An external current affecting the body.
Tissue injury caused by electrical heating.
Death from electric shock.
Health and Safety Executive: Electrical injuries · Health and Safety Executive: Selection and use of electric handlamps, PM38 · NHS: Burns and scaldsRead all anatomy and process explanations without the viewer
General occupational awareness of anatomy and incident mechanisms. A broad term for injury associated with electrical exposure. An external current affecting the body. Tissue injury caused by electrical heating. Death from electric shock. Electrical rescue, live testing, isolation or energised work instruction An energise-person control, contact timer, voltage or resistance input Safe current paths, survival percentages or shock-severity scores ECG interpretation, rhythm selection or AED shock decisions Medical or workplace clearance from a mark, diagram or feeling well The hazard-avoidance and medical-help panel is visible before model loading and quiz completion.
Nerve pathway
Nerves communicate using electrical and chemical signals. Nerves carry biological signals, and communication at the nerve-to-muscle connection helps activate muscle. The travelling cue is a simplified way of directing attention to that relationship. It does not show household current circulating through a person, and its colour, speed or brightness cannot be used to interpret nerve function or electrical injury. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling · Oxford University Hospitals NHS Foundation Trust: Nerve Conduction Studies and Electromyography
Skeletal muscle
The nervous system normally coordinates muscle contraction. A slow hand movement demonstrates normal function; it does not imitate a casualty’s involuntary movements. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling
Breathing muscles
Coordinated muscle activity helps move air into and out of the lungs. The diaphragm and chest movement belong to the respiratory lesson. This example shows no breathing-rate measurement. Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role
Heart conduction
Coordinated electrical activity helps organise the heart’s pumping. A labelled sequence illustrates normal biological activation. It is not an ECG or a rhythm-interpretation exercise. St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system · NHS 111 Wales: Cardiac Arrest
Skin contact region
Contact conditions influence how an electrical exposure affects the body. The marker identifies an example contact region. It does not calculate skin resistance or identify a safe point to touch. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Internal tissue region
Electrical injury can extend beneath the visible surface. An electrical incident can cause effects below the surface, so visible appearance alone cannot describe the whole injury. This transparent region marks the subject of the explanation, rather than a measured boundary of damage. Its shape does not establish where current travelled or which tissues are unaffected; compare it with the selected mechanism caption. Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns
External source
The incident hazard comes from an electrical source outside the body. The generic equipment symbol is kept disconnected from the normal biological signalling diagram. Health and Safety Executive: Introduction to electrical safety
Illustrative exposure route
This broad region represents one possible exposure route. It cannot establish the actual route or outcome. There is no safe-path selector, voltage control or timed-contact exercise. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Arc and thermal region
An arc or hot electrical equipment can cause injury. This separate incident panel is different from a simple through-body current diagram. No arc flash is animated. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
Secondary injury
Loss of control can lead to falls or contact with nearby hazards. The neutral surrounding-hazard symbol recognises these injuries without staging a fall or body jerk. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
Response boundary
Keep clear of unresolved electrical danger and get emergency help. Do not touch a person who may still be in contact with an electrical source. This node opens the safety panel, never a rescue activity. Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electricity — electric shock and overhead-line precautions · Health and Safety Executive: Emergency procedures
Open the complete process transcript
The process, step by step
Explore normal function
Start with the body’s own signalling: nerves communicate with muscles, breathing muscles move the chest, and organised activation coordinates the heart. Select one example at a time and read the associated label before changing systems. These are normal biological functions, not electricity from equipment moving through a person. The slow cues make the explanation easier to follow; they do not show a measured nerve signal, breathing rate or heart rhythm. This process sequence is a teaching route through the subject, not a simulation of an electrical accident. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling · Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role · St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system
What to watch: Select the nerve, skeletal-muscle, breathing-muscle and heart labels individually, noticing that each belongs to a different normal biological example.
Why it matters: Normal signalling helps muscles work in a coordinated way. Keeping these biological examples distinct from the incident diagrams makes it easier to explain what an external electrical hazard can disrupt.
Explore this step: Explore one normal system, then explain its function before selecting a different system.
Locate the external hazard
Locate the generic electrical-source symbol outside the body and compare it with the normal biological labels. It represents an external workplace hazard, not the source of ordinary nerve or heart signalling. The model keeps the equipment symbol separate and does not energise the silhouette when a learner selects it. This step establishes the context before the different injury mechanisms are discussed. A picture of equipment cannot show whether real equipment is safe. Use the label to identify the distinction, rather than imagining that the model is testing a circuit. Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Emergency procedures
What to watch: Locate the external-source symbol and the response-boundary label, then compare their positions with the normal body-system labels.
Why it matters: An external electrical supply is a hazard that requires competent control. Separating it from biological signalling avoids implying that a normal nerve pathway describes a safe route for electrical current.
Explore this step: Identify which labels describe the body and which identify the external hazard or safety boundary.
Choose an incident example
Choose one incident explanation: electric shock, electrical heating within tissue, or an arc and its thermal effects. These are different mechanisms and more than one may be relevant to an incident. Read the selected heading before examining the highlighted region so that the image and explanation remain connected. The model is a route through the concepts, not a calculation of current flow or injury severity. It provides no voltage control, safe-contact experiment or animated arc. Compare the labels to explain how the mechanisms differ without ranking an actual casualty’s injuries. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
What to watch: Read the incident heading, then locate its contact, internal-tissue or arc-and-thermal label rather than combining every marker into one route.
Why it matters: Shock can disturb body function, while heating can injure tissue. An arc can cause thermal injury without being equivalent to the simple contact diagram; the examples can overlap in a real incident.
Explore this step: Compare two incident panels and describe the different mechanism named by each heading.
Explain possible effects
Read the caption beside the selected system and trace the labelled relationship being explained. Electric shock can interfere with muscle control, breathing or the way the heart beats; electrical heating can damage tissue. The highlighted region is a teaching focus, not a map of an individual’s injury. It cannot identify the actual route through the body or declare that an unhighlighted organ is unaffected. Compare the normal-function labels with the incident caption, keeping the possible effect separate from any claim about what has happened to a particular person. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
What to watch: Compare the breathing-muscle, heart and internal-tissue labels with the caption for the incident mechanism currently selected.
Why it matters: Interference with coordinated muscle or heart function can be serious even when an illustration shows little surface change. A teaching marker cannot determine which effects are present or absent in a real person.
Explore this step: Choose a system and describe its normal role before reading the possible effect in the incident caption.
Know the limits
Finish by comparing the questions the diagram answers with those it cannot answer. It can introduce normal signalling and distinguish several possible injury mechanisms. It cannot establish an actual exposure, the extent of damage, a safe electrical condition or medical clearance. A small-looking electrical burn or feeling well does not provide that clearance. The external-source and response-boundary labels keep these limits visible. Review them alongside the existing safety panel; completing this teaching route is not a rescue procedure, a clinical assessment or permission to resume the work. NHS: Burns and scalds · Health and Safety Executive: Electrical safety frequently asked questions · NHS 111 Wales: Burns and scalds — electrical burns
What to watch: Locate the internal-tissue and response-boundary labels, then compare the limits stated in their captions with the incident explanation.
Why it matters: Visible appearance alone cannot establish the seriousness of electrical injury. Keeping the model’s scope clear prevents an explanatory picture or completed activity being mistaken for evidence that a person or workplace is safe.
Explore this step: Name one question the model explains and one question that requires assessment beyond this teaching view.
Mechanisms and their limits
Electric shock: disruption of normal function External electrical current can interfere with muscle control, breathing or the heart’s organised activity. These are possible effects; the same diagram cannot predict the outcome of a real incident. An illustrative route does not show that a particular organ must or cannot be affected. No arbitrary arrhythmia, dramatic flatline, body jerk or calculated survival result is shown. Both alternating and direct current can be dangerous. The viewer offers no safe voltage or safe path. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
HSE: prevent electrical injury
Electrical heating: injury beneath the surface Current passing through tissues can generate heat and cause burns beneath the skin. A small visible mark is not enough to judge the internal effects. Not every shock produces extensive burns. The marked region is illustrative, not a reconstructed path, calculated burn depth or severity score. An electrical burn needs emergency medical assessment even if it appears small. Feeling well or selecting a similar image does not provide workplace or medical clearance. Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns
NHS: electrical burns need emergency care
HSE: electrical injury mechanisms
Arc, heat and secondary injury Arcing and hot electrical equipment can injure people without the event fitting a simple hand-to-foot contact story. Heat, fire or explosion and secondary falls or nearby machinery may add hazards. The diagram does not require a through-body route to recognise an arc or thermal hazard. Alternating and direct current equipment can both present hazards. This is an incident explanation, not a flash-energy calculation or permission to approach damaged equipment. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electrical safety frequently asked questions
HSE: electrical hazards and controls
HSE: competent assessment of unsafe equipment
Electric shock: disruption of normal function — follow the anatomy
Look at: The contact route through the body, including nerves and muscle.
What changes: Electric current can interfere with normal nerve, muscle, breathing or heart activity.
Why it matters: A person may be unable to let go, collapse or develop a dangerous rhythm.
What to do: Keep clear, do not touch anyone still in contact with electricity, call 999 and follow competent site emergency arrangements.
Damaged portable equipment presents an unresolved electrical hazard
A worker finds damaged equipment near a damp work area; the exposure is a counterfactual failure of controls, not a rescue exercise. An acute incident is explained in 32 seconds without voltage, current or contact-duration inputs. The sequence sets no safe exposure or waiting time. Never touch a person or equipment while electrical danger is unresolved. The viewer cannot prove isolation or infer the actual current path or outcome.
Keep clear of the unresolved source Damaged equipment in a damp area is a stop-and-report situation. Do not touch a potentially live casualty; call appropriate help and use competent site emergency arrangements. Health and Safety Executive: Electrical safety frequently asked questions · Health and Safety Executive: Emergency procedures
What failed barriers could allow The counterfactual contact example marks an external source and possible exposure. It does not ask the learner to energise a person or select a supposedly safe route. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Possible interference with normal function External current can affect muscle control, breathing or heart function. These are possible effects, not a prediction that every organ is involved or that a particular contact is survivable. Health and Safety Executive: Electrical injuries
Safety first, then urgent assessment Keep clear and obtain emergency help while danger remains. Only once the scene is safe does the separate unresponsive/abnormal-breathing CPR/AED guidance apply. Feeling well does not provide medical or equipment clearance. Health and Safety Executive: Electrical safety frequently asked questions · NHS: Burns and scalds · NHS 111 Wales: Cardiac Arrest · Health and Safety Executive: Emergency procedures
Electrical heating: injury beneath the surface — follow the anatomy
Look at: The tissue beneath the electrical contact points.
What changes: Current can generate heat inside the body as well as at the skin.
Why it matters: A small visible mark can conceal serious deeper injury.
What to do: Keep the scene safe; electrical burns need 999 or A&E assessment even when the visible mark is small.
A small external mark after an electrical incident
After an electrical incident, a worker has a small visible hand mark; the area must be made safe by competent arrangements. This is a possible injury explanation, not a burn-depth model or a simulation of tissue heating at a selected exposure time. Visible marks cannot establish the route or depth of internal injury. Not every shock produces the broad affected area used in this illustration.
Do not approach unresolved energy danger The incident is treated as an electrical emergency until the scene is safe. Keep clear, summon appropriate help and do not judge safety from a small mark. Health and Safety Executive: Electrical safety frequently asked questions · NHS: Burns and scalds
External current can heat tissues A broad translucent region represents possible tissue heating during contact. It is not a wire tracing the real route and it does not calculate dose from a contact point. Health and Safety Executive: Electrical injuries
An external mark may understate injury The selected region separates possible internal effects from the skin marker. Size or appearance of the mark cannot clear the person or tell the learner what tissues were actually injured. Health and Safety Executive: Electrical injuries · NHS 111 Wales: Burns and scalds — electrical burns
Arrange medical assessment Use emergency help for electrical burns and follow live advice once it is safe to assist. Do not continue work or reassure someone simply because the mark is small; the activity gives no treatment or return-to-work clearance. NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns · Health and Safety Executive: Emergency procedures
Arc, heat and secondary injury — follow the anatomy
Look at: The skin and eyes facing the arc, and the worker’s surroundings.
What changes: An electrical arc releases intense heat; the event may also cause a fall or other trauma.
Why it matters: Burns and secondary injuries can occur without a current path through the body.
What to do: Control arc hazards, use competent isolation procedures and plan emergency response.
An electrical fault releases heat near a work area
A fault or overheated electrical component exposes people nearby to heat and possible secondary hazards. The short explanation omits flashes, noise and blast effects. It predicts no arc boundary, burn depth, safe distance or survival probability. Arc/thermal injury is separate from the through-body current example. A person need not supply a hand-to-foot contact story for the incident to be serious.
Treat the fault as unresolved danger Keep clear of faulty or overheated equipment and activate competent emergency arrangements. The example gives no permission for live inspection or repair. Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electrical safety frequently asked questions · Health and Safety Executive: Emergency procedures
Heat can be released without the chosen contact route The equipment-and-person schematic marks hot material or thermal exposure. No bright flash or energise-person action is used to teach the incident. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
Possible thermal and secondary injury Heat may injure tissue, and a loss of control or sudden movement may lead to falls or contact with surrounding hazards. These possibilities remain separate from a reconstructed internal current path. Health and Safety Executive: Electrical injuries
Control the danger and get help Follow site emergency arrangements and obtain medical help for injuries once safe to assist. Competent investigation must address the fault; no visual improvement in the model clears the equipment or the worker. NHS: Burns and scalds · Health and Safety Executive: Electrical safety frequently asked questions · Health and Safety Executive: Emergency procedures
Read the practice situations and all answer explanations
EL-Q1: What can be concluded from the mark?
A colleague has had an electrical incident and has only a small visible mark.
It proves the event was harmless. — A small mark cannot rule out internal effects. Electrical burns need emergency care.
Internal effects cannot be judged from the mark; seek appropriate medical assessment. — Correct. Do not use appearance as reassurance. Keep the area safe and obtain appropriate medical help; an electrical burn requires 999 or A&E.
Select the closest route in the model to calculate survival. — The model cannot reconstruct the incident or predict survival. Seek appropriate help instead of matching an image.
Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burnsEL-Q2: Which response avoids creating another casualty?
Someone may still be in contact with a live electrical source.
Touch them immediately to pull them away. — Do not touch them while the electrical danger is unresolved. You could also be injured. Call for emergency help.
Keep clear, call emergency help and follow competent site emergency arrangements. — Correct. Call 999 and explain that electricity is involved. Keep others clear and follow competent emergency arrangements; this lesson does not teach electrical rescue or isolation.
Use the viewer to find the safest current path. — There is no safe-path or rescue method in this viewer. Keep clear and get emergency help.
Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electricity — electric shock and overhead-line precautions · Health and Safety Executive: Emergency proceduresEL-Q3: What still needs consideration?
An arc incident happens without an obvious hand-to-foot contact route.
There cannot be an injury without that route. — A simple through-body route is not required for an arc/thermal injury or a secondary fall.
Arc, heat and secondary injuries. — Yes. Consider the incident hazards and obtain appropriate help rather than forcing the event into one current-path drawing.
Direct-current equipment cannot cause harm. — Both AC and DC equipment can be hazardous. Neither label provides reassurance.
Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electrical safety frequently asked questionsSources and how the model is made
The opening images are AI-generated anatomical illustrations. The interactive 3D models and labelled SVG diagrams use original procedural artwork. These teaching images are not medical scans or diagnostic tools. Source references support the learner explanations and do not grant artwork rights.
- Health and Safety Executive: Electrical injuries — Possible shock effects, deep tissue heating, loss of muscle control, thermal and secondary injuries; AC and DC hazards. No numerical voltage/contact-time thresholds transferred.
- Health and Safety Executive: Introduction to electrical safety — Contact, arcing, fire/explosion and secondary falls; suitable equipment and competent maintenance/assessment. No isolation or live-work procedure generated.
- Health and Safety Executive: Selection and use of electric handlamps, PM38 — Page 1 defines electrocution as death from electric shock; replaces the brief’s US terminology source. No equipment specification or voltage rule copied into this awareness lesson.
- NHS: Burns and scalds — Current page reviewed 31 March 2026: electrical burns require 999 or A&E. No chemical-skin or eye-irrigation timer substituted.
- Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function — Basic biological electrical signalling and motor/sensory roles only. No paediatric injury prognosis or treatment transferred to the occupational module.
- NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling — Normal nerve signalling followed by chemical communication to activate muscle. Disease mechanisms and treatment are outside this module.
- Oxford University Hospitals NHS Foundation Trust: Nerve Conduction Studies and Electromyography — Natural electrical signals in nerves and muscle activity. No diagnostic procedure, test voltage or stimulation activity reused.
- Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role — Diaphragm movement and air movement during breathing only. No exercise programme, self-assessment or rate target reused.
- St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system — Page 2 normal cardiac electrical activation coordinating contraction. Printed review date October 2026 needs recheck at sign-off. No clinical procedure, ECG or third-party artwork copied.
- Health and Safety Executive: Electrical safety frequently asked questions — AC/DC hazards, multifactorial outcome uncertainty and need for competent safety assessment. No safe-voltage, resistance, RCD guarantee or risk score imported.
- NHS 111 Wales: Burns and scalds — electrical burns — A small-looking electrical burn can be very damaging and needs immediate medical attention. No household separation/rescue procedure copied.
- NHS 111 Wales: Cardiac Arrest — Unresponsive and absent/abnormal breathing, gasping, immediate 999/CPR/call-handler/AED recognition pathway. Applies only after electrical danger is resolved. No clinical ECG decision or full CPR course.
- Health and Safety Executive: Electricity — electric shock and overhead-line precautions — Do not touch a casualty while electrical danger remains; stay clear and warn others; first aid requires training. No separation technique, escape manoeuvre or rescue distance imported.
- Health and Safety Executive: Emergency procedures — Competent emergency control, calling emergency services, site arrangements and no resumption while serious danger remains. No procedural isolation instruction generated.
What causes electrocution injuries at work?
Electrocution injuries are caused by contact with live parts, faulty equipment, poor isolation, unsafe environments or uncontrolled electrical services.
Most workplace causes are predictable: damaged leads, exposed terminals, missing covers, wet tools, poor maintenance, work on live systems, incorrect isolation, unsuitable test equipment, excavation strikes, overhead-line contact and overloaded electrical equipment. The hazard may be obvious, such as an open panel, or hidden, such as a buried cable or energised circuit thought to be dead.
A useful investigation avoids the phrase 'worker touched electricity' as the cause. It asks why live electricity was accessible, why the work method allowed exposure, what information was missing, whether the person was competent and whether supervisors had evidence that controls were in place.
| Cause | How harm occurs | Examples |
|---|---|---|
| Live parts | Person contacts exposed conductor or terminal. | Open panel, damaged socket, missing cover. |
| Poor isolation | Equipment remains energised during work. | Lock-off missing or not proved dead. |
| Damaged equipment | Fault makes casing, tool or lead dangerous. | Cut cable, cracked plug, overheating charger. |
| Wet conditions | Reduced resistance increases shock risk. | Outdoor tools, washdown or damp excavation. |
| Overhead lines | Plant or materials contact or approach live conductors. | MEWP, crane, ladder or tipper body. |
| Underground cables | Digging damages live electrical service. | Excavator, breaker, post driver or hand tool. |
What affects the severity of electrocution injuries?
Severity depends on the energy, current path, contact duration, environment, rescue speed and secondary consequences.
Voltage is important, but not enough on its own. Current path, time in contact, moisture, skin condition, footwear, conductive surroundings, frequency, ability to let go and whether the person is working at height all affect the outcome. A shock while standing on a dry floor is different from a shock in a wet trench, on a ladder or inside metal plant.
The workplace should treat severity factors as design information. If conditions are wet, cramped, conductive, remote, elevated, high-energy or near flammable substances, controls should be stronger and emergency arrangements more explicit.
| Factor | Why it matters | Control implication |
|---|---|---|
| Current path | Path across chest can affect heart. | Prevent contact and isolate. |
| Contact time | Longer exposure worsens shock and burns. | Rapid disconnection and rescue planning. |
| Wetness | Moisture reduces body resistance. | Use suitable equipment and RCD protection. |
| Work at height | Shock can cause falls. | Control electricity before elevated work. |
| High fault energy | Arc flash and blast become credible. | Competent electrical work and barriers. |
| Remote location | Response may be delayed. | Lone working and emergency planning. |
How do arc flash and electrical burns differ from ordinary shock?
Arc flash and electrical burns can cause severe injury even when a person is not holding a live conductor.
Electric shock usually involves current passing through the body. Arc flash involves electrical energy travelling through air after a fault, creating intense heat, light, sound, pressure and molten metal. The person may suffer burns to face, hands and body, eye injury, hearing damage or blast trauma.
Electrical burns can be deep because current heats tissue internally. A small contact mark may not show underlying injury. This is why site arrangements should not assume that someone is safe because they walked away from the incident.
| Type | Main route | Prevention focus |
|---|---|---|
| Electric shock | Current through body. | Isolation, enclosure and protection. |
| Electrical contact burn | Current heats tissue at contact points. | Prevent contact and fault exposure. |
| Arc-flash burn | Fault energy heats air and surfaces. | Safe systems, barriers and competence. |
| Thermal burn | Hot equipment or explosion causes burn. | Maintenance and overload prevention. |
| Blast trauma | Pressure wave causes impact or hearing injury. | Fault-energy control and exclusion. |
How can the hierarchy of controls prevent electric shock during investigation of faulty equipment?
Use HSE’s hierarchy to eliminate or substitute a hazard where practicable, then apply engineering and administrative controls before relying on PPE. Check each chosen control against the actual task and stop when it fails.
Verify controls: Diagnosing an electrical equipment fault
Read the complete visual as text
- Actual task: A faulty item needs investigation after a reported electric shock concern. Keep it out of use and prioritise removal of electrical contact; emergency care and incident preservation follow their own immediate routes.
- Evidence to check: circuit identity, all supplies, safe isolation and suitable test equipment
- Stop or hold condition: uncertain circuit, unexpected voltage or an unapproved need for live access
- Release evidence and owner: competent electrical owner accepts completed tests and safe reinstatement
The strongest control is to avoid electrical danger altogether: design equipment so live parts are enclosed, plan work dead, remove damaged equipment from use and avoid working near live overhead or underground services. Where electricity cannot be eliminated, reduce energy, isolate, guard, segregate, inspect and authorise competent people.
PPE, signs and briefings support the system, but they do not compensate for poor isolation, damaged cables, live exposed parts or inadequate supervision. Prevention should be visible in the workplace through maintained equipment, clear stop-work rules, competent electrical work and timely action on defects.
Which legal duties apply to electrocution injury prevention?
Great Britain and Northern Ireland use separate safety instruments; choose the rule for the site and the activity.
| Where | Instrument | Practical duty boundary |
|---|---|---|
| Great Britain | Electricity at Work Regulations 1989 | Prevent danger in electrical systems and work. |
| Northern Ireland | Electricity at Work Regulations (Northern Ireland) 1991 | Apply NI electrical-work duties. |
| Great Britain | Health and Safety at Work etc. Act 1974 | Protect employees and others affected by work. |
| Northern Ireland | Health and Safety at Work (Northern Ireland) Order 1978 | Apply NI general work-safety duties. |
| Great Britain | Management Regulations 1999 | Assess risks and make management arrangements. |
| Northern Ireland | Management of Health and Safety at Work Regulations (Northern Ireland) 2000 | Assess risks and make NI management arrangements. |
| Great Britain | RIDDOR 2013 | Report only incidents within the applicable GB categories and timescales. |
| Northern Ireland | RIDDOR (Northern Ireland) 1997 | Check the NI 1997 reporting categories and route with HSENI; GB 2013 changes do not apply. |
Electrical duties apply to systems and work; DSEAR applies to dangerous-substance fire and explosion scenarios, and construction or injury-reporting rules apply only within their stated scope. A guidance document or standard is not itself the legal instrument.
How should electrocution injuries and near misses be reported and investigated?
Electrical injuries and near misses should be reported promptly, made safe, classified correctly and investigated to identify failed controls.
The first priority is safety and medical support. Once people are safe, the organisation should preserve evidence: equipment, leads, plugs, test instruments, permits, isolation points, photos, witness accounts, weather, floor condition, PPE, work instructions and training records. Damaged equipment should not be put back into use before examination by a competent person.
Investigation should work backwards from the harm route. What was live? How did the person contact it or get exposed to arc energy? Was the system supposed to be isolated? Who authorised the work? What inspections existed? Were defects known? Did production pressure, contractor interface or unclear information weaken the controls?
| Evidence type | Why it matters | Example |
|---|---|---|
| Energy source | Identifies what delivered current or fault energy. | Circuit, cable, battery, charger or line. |
| Isolation status | Tests whether the safe system worked. | Lock-off and proof-dead evidence. |
| Equipment condition | Shows defects or poor maintenance. | Damaged lead, exposed conductor or scorch mark. |
| People and competence | Checks authorisation and understanding. | Training, supervision and contractor records. |
| Environment | Explains severity factors. | Wet floor, height, metalwork or poor lighting. |
| Management actions | Shows whether learning will be completed. | Action tracker with verification. |
Preserve the scene where safe, remove the equipment from service and record the source, circuit, isolation state and witnesses. Check the applicable GB or NI reporting route against the actual injury and event category; do not assume that every shock is automatically a RIDDOR report. See HSE RIDDOR reportable incidents. For Northern Ireland, use HSENI reporting guidance; its rules differ from GB RIDDOR 2013.
Worked comparison: a worker has an electrical burn and is admitted to hospital for more than 24 hours. In Great Britain, test the injury against RIDDOR 2013 categories: a burn is a specified injury if it covers more than 10% of the body or significantly damages the eyes, respiratory system or other vital organs; check other categories such as over-seven-day incapacity as facts develop. Electric shock alone is not a named GB specified injury. In Northern Ireland, the NI major-injury category expressly includes shock or electrical burn causing unconsciousness, requiring resuscitation or hospital admission for more than 24 hours. Record the clinical facts and apply the rule for the site; other reportable categories may also apply. See HSE GB specified-injury criteria and HSENI Northern Ireland major-injury guidance.
What should a risk register include for electrocution injuries?
The risk register should describe credible electrical injury scenarios and the evidence that prevents each one.
A useful register separates different routes to injury. Contact with live parts is not the same as arc flash, overhead-line contact, underground cable strike, portable-equipment fault or wet-condition tool use. Each scenario needs specific controls and owners.
The register should also include early-warning indicators: repeated equipment defects, RCD trips, overdue inspection, unclear isolations, poor contractor handover, live-work requests, damaged chargers and near misses.
| Scenario | Possible injury | Evidence |
|---|---|---|
| Worker uses damaged extension lead. | Shock or burns. | User checks and quarantine records. |
| Electrician works on panel not proved dead. | Fatal shock or arc flash. | Isolation certificate and test record. |
| Excavator strikes live cable. | Electrocution and arc burns. | HSG47 controls and permit to dig. |
| MEWP contacts overhead line. | Fatal shock and ground potential hazard. | GS6 planning and exclusion zones. |
| Tool used in wet area. | Shock and secondary fall. | Suitable equipment and RCD checks. |
| Charger overheats overnight. | Fire and burns. | Charging policy and inspection. |
What training is needed to prevent electrocution injuries?
Training should help people recognise electrical danger, stay within competence and act correctly after a shock or near miss.
General awareness should cover shock, burns, damaged cables, unsafe charging, wet conditions, overhead lines, buried cables and reporting. Short topical training should be provided for workers using portable tools, supervisors controlling temporary electrics, groundworkers near buried services and plant operators near overhead lines.
Supervisors and managers need deeper training on electrical risk assessment, contractor control, isolation evidence, incident investigation, RIDDOR decision making and assurance. Technical electrical work requires formal competence and authorisation.
| Role | Learning | Demonstration | Assessor | Record | Reassess when |
|---|---|---|---|---|---|
| Witnesses and nearby workers | Recognise live-contact danger, stay clear, raise alarm | Explain why they must not touch a connected casualty | Supervisor | Observed emergency drill | New site or missed alarm |
| Equipment users | Spot damaged leads and stop use before an injury | Quarantine an unsafe item and identify isolation contact | Task supervisor | Observed pre-use check and defect record | New equipment or defect |
| Appointed first aiders | Scene safety, emergency call, primary survey and care within training | Demonstrate safe approach, primary survey and CPR/AED response on a drill mannequin | Qualified first-aid assessor | Current first-aid qualification and drill record | Qualification renewal or changed emergency plan |
| Electrical responders | Identify every supply, isolate and confirm the scene is safe | Demonstrate lock-off and proof-dead before rescue access | Competent electrical lead | Technical authorisation and drill | Changed system or failed isolation |
| Supervisors and permit issuers | Coordinate emergency access, medical handover and controlled restart | Lead a scenario without touching the casualty before isolation | Emergency-plan lead | Exercise and incident record | Changed work area or incident |
| Managers and investigators | Preserve evidence, classify GB/NI reports and correct failed controls | Apply local reporting criteria to a case and verify action closure | Competent safety/legal reviewer | Decision record and action closure | Law change or significant event |
| Safety advisers and auditors | Check source scope, report route and effectiveness of learning | Trace one injury to physical-control improvement | Independent competent reviewer | Audit and action record | New evidence or repeat exposure |
Course attendance is only one input. Observe performance on the actual task, record the scope of authorisation and reassess after change, defect or incident. First aid and electrical repair require different competence.
How does electrocution injury knowledge support NEBOSH study?
This topic supports NEBOSH study by connecting health outcome, hazard mechanism, controls and investigation evidence.
For general, construction and diploma-level study, strong answers explain how shock occurs, why severity changes, how burns and arc flash differ, and what controls prevent exposure. Learners should be able to apply the topic to portable tools, wet conditions, overhead lines, buried cables, electrical contractors, isolation and incident response.
Scenario-based answers should move from mechanism to control. For example: a worker shocked by a damaged tool in a wet area needs analysis of equipment condition, pre-use checks, environment, RCD protection, supervision, training, first response, reporting and recurrence prevention.
How can management arrangements support this topic?
HSE’s Plan–Do–Check–Act guidance helps assign ownership, deliver controls, check evidence and improve weak arrangements. Apply the relevant legal duties and task-specific technical evidence separately.
Official management guidance: HSE Managing for health and safety (HSG65)
HSE’s Plan–Do–Check–Act guidance helps assign ownership, deliver controls, check evidence and improve weak arrangements. Apply the relevant legal duties and task-specific technical evidence separately.
What are the warning signs that electrocution injury risk is not controlled?
Warning signs appear when damaged equipment, unclear isolation, unsafe environments or weak learning become normal.
Many serious electrical incidents are preceded by weak signals: repeated cable damage, reset trips, temporary repairs, scorch marks, missing covers, damp tools, unlabelled isolators, poor contractor handover, unclear drawings or workers saying they have had 'small shocks' before.
These warning signs can lead to harm because they leave people exposed to live energy, increase contact time, delay rescue or allow the same fault to recur until conditions are more severe.
| Warning sign | How harm can manifest | Action |
|---|---|---|
| Minor shocks are dismissed | Same fault may later injure someone severely. | Report and investigate every shock. |
| Taped cable repair | Insulation may fail and expose live conductors. | Remove from use. |
| RCD trips repeatedly | Fault or overload may be ignored. | Investigate root cause. |
| Unclear isolation | Worker may contact live parts believing them dead. | Lock off and prove dead. |
| Wet tools or leads | Current may pass more easily through body. | Use suitable equipment and stop wet-use shortcuts. |
| Poor rescue knowledge | Responder may touch an energised casualty. | Brief isolation and emergency response. |
What do the acronyms and key terms mean?
Explaining electrical and injury terms helps non-specialists understand the prevention controls.
| Term | Full expansion | Meaning here |
|---|---|---|
| AC | Alternating current | Alternating Current. |
| Arc flash | Arc flash | Sudden release of electrical fault energy through air. |
| DC | Direct current | Direct Current. |
| EAWR | Electricity at Work Regulations | Electricity at Work Regulations. |
| Electrocution | Electrocution | Commonly used to describe fatal electric shock. |
| GS38 | Guidance Series 38 | HSE guidance on electrical test equipment. |
| PAT | Portable appliance testing | Portable Appliance Testing. |
| PPE | Personal protective equipment | Personal Protective Equipment. |
| RCD | Residual current device | Residual Current Device. |
| RIDDOR | Reporting of Injuries, Diseases and Dangerous Occurrences Regulations | Reporting of Injuries, Diseases and Dangerous Occurrences Regulations. |