Portable Electrical Equipment
Portable electrical equipment ranges from a static office charger to a hand-held tool or cleaning machine. Damaged cables, unsuitable equipment and wet or rough use can allow shock, burns or fire; the maintenance decision depends on the equipment and the conditions of use. User checks, visual inspection and electrical testing each address different faults, and there is no universal annual portable appliance test requirement.
Understanding Portable Electrical Equipment
Portable electrical equipment ranges from a static office charger to a hand-held tool or cleaning machine. Damaged cables, unsuitable equipment and wet or rough use can allow shock, burns or fire; the maintenance decision depends on the equipment and the conditions of use. User checks, visual inspection and electrical testing each address different faults, and there is no universal annual portable appliance test requirement.
Why this matters at work
Describe the task, environment and credible damage route before setting the maintenance plan. Look at dragging, bending, crushing, vibration, heat, liquids, dust and repeated connection. Consider bystanders and downstream consequences of a fire as well as the person holding the device. Do not use a successful appliance test as permission to ignore a frayed cable, incorrect plug, unsuitable enclosure or overloaded supply. Remove dangerous equipment immediately and investigate the conditions that produced the fault.
Damaged insulation, loss of earth continuity, poor termination, unsuitable voltage, water ingress and overheating can lead to shock, burns or fire. A person can also fall or lose control of a tool after a shock. The fault mechanism matters because no single check detects all of them. Visible damage is often the first warning, while a broken conductor inside a flexible cable or deteriorated insulation may require a suitable electrical test.
How organisations manage this in practice
Management review should test whether the system prevents danger, not celebrate the number of items tested. Examine user reports, inspection findings, electrical failures, fires, shocks, RCD operations, repairs, overdue work, inaccessible assets, recalls and contractor quality by equipment type and location. Increasing failure can indicate unsuitable procurement, cable routing, environment, training or interval. A very low recorded failure rate may also indicate superficial inspection or missing populations rather than excellent control.
Electrical maintenance duties follow control, not simply ownership. Employers, relevant self-employed people and employees have duties under electrical law, while PUWER can apply to employers and people who control work equipment or its use to the extent of that control. A host, contractor, landlord, hire company, facilities provider and equipment owner may each control different decisions. Buying a PAT service does not transfer the dutyholders overall responsibility to decide whether the maintenance system prevents danger.
Maintenance assurance asks whether the controls work between inspections. Sample real equipment, cables and sockets alongside the register. Compare moving tools with static equipment, recent repairs with release evidence, and contractor results with the agreed scope. Missing items, swapped leads and inaccessible equipment require named follow-up. Workers need a defect route that remains usable when software, labels or remote support fail.

Temporary electrical supplies: follow the path to shock and fire
Explore how this equipment can harm its users and other people, then follow the practical measures that interrupt each pathway. This is a hazards and good-practice lesson; the separate checklist remains the pre-use/safety-check activity.
Hazards and good practice: learn what can hurt people during use, change and maintenance. Pre-use and safety checks stay in the separate checklist.
Checksheets and risk assessments
Equipment checksheets
- Site electrical distribution and RCD checks — 3D checks · Word · PDF
- Generators and temporary power supplies — 3D checks · Word · PDF
Risk assessment examples
Full written walkthrough — all 8 steps
1. Plan a suitable supply and work setting
What is happening: The distribution unit connects a source, protective devices, cables and equipment in a changing workplace.
How harm can occur: Unsuitable equipment or arrangements can expose users and other trades to shock, burns, arc or fire.
Best practice to apply: Use competent design and selection for the actual work, supply and environment; reduce avoidable electrical exposure.
Why this works: Suitable selection controls the hazard before a person has to work near the system.
Electrical hazards and risks · How should an electrical hazard be traced?2. Understand the contact pathway
What is happening: A live part or fault can connect the supply through a person to another conductive surface.
How harm can occur: Current through the body can cause serious injury; arcing can cause burns without the same direct contact.
Best practice to apply: Keep live parts enclosed and inaccessible and use the actual protective arrangements; never open this example as a user instruction.
Why this works: Preventing access interrupts contact; appearance and a healthy-looking cable do not establish an electrically safe system.
Electrical hazards and risks · Separate contact, arc, ignition and secondary injury3. Protect cables in the real work route
What is happening: Leads cross areas where vehicles, sharp edges, water and other operations may affect them.
How harm can occur: Damage or unsuitable routing can expose conductors, start a fire or create a trip leading to secondary injury.
Best practice to apply: Use appropriate routing and mechanical/environmental protection and respond to damage without makeshift live repairs.
Why this works: The route is part of the electrical risk, even when the connected tool has no visible defect.
Electrical hazards and risks · Why do wet environments increase electrical risk?4. Keep protective functions in context
What is happening: An RCD is one protective measure within a complete system, not permission to use a damaged supply.
How harm can occur: Some faults, contact conditions and other hazards are not removed simply because an RCD is fitted.
Best practice to apply: Use suitable competent selection, installation and verification; retain other required protection and the instructed user checks.
Why this works: A single protective device cannot stand in for correct system design and continued condition.
Electrical hazards and risks · How can the hierarchy of controls reduce risks while using portable power for a site repair?5. Maintain enclosure and access boundaries
What is happening: The sealed cover separates users from internal components and keeps the operating interface distinct.
How harm can occur: Opening or defeating protection can create access to energy that a routine user cannot safely assess.
Best practice to apply: Keep covers and restricted areas secure; refer faults or access needs to the responsible competent electrical person.
Why this works: Routine operation and intrusive electrical work require different competence and control arrangements.
Electrical hazards and risks · What training and competence are needed for electrical hazards?6. Recognise stop and isolation as different actions
What is happening: A switch indication or an inactive tool does not identify every source of electrical or other stored energy.
How harm can occur: A backup, battery, control circuit or other source can cause unexpected energisation or movement.
Best practice to apply: Plan dead work through the actual competent isolation, securing and verification procedure; this lesson does not teach live testing.
Why this works: System-specific identification and verification address sources that a simple stop can leave present.
Electrical hazards and risks · How can electricity injure the body, and why can a small mark hide a serious incident?7. Deal with an unsafe condition without touching danger
What is happening: A damaged supply or casualty may still be connected to continuing electrical danger.
How harm can occur: A rescuer or colleague can become a second casualty by approaching or touching too soon.
Best practice to apply: Keep people clear, use the site's emergency arrangements and have the continuing danger controlled; do not improvise a repair or rescue contact.
Why this works: Preventing additional contact protects people while competent emergency help and isolation are arranged.
Electrical hazards and risks · What are the secondary effects of electrical incidents?8. Return equipment only after competent resolution
What is happening: A replaced cable or reset trip does not by itself explain the fault or prove that the installation is suitable.
How harm can occur: The same fault can recur and harm the next user or an adjacent trade.
Best practice to apply: Record and restrict defective equipment, resolve the cause and have the necessary verification and handover completed.
Why this works: A verified repair and clear restrictions prevent a temporary reset being mistaken for a safe hand-back.
Electrical hazards and risks · How can the hierarchy of controls reduce risks while using portable power for a site repair?
Illustrative awareness learning. Geometry, colours and movement do not establish safe distances, capacity, exposure, isolation or work permission. Use the actual assessment, equipment information and competent arrangements.
The wider workplace has its own account and subscription access. Exploring this lesson does not grant access, record course completion or authorise work.
UK guidance for further reading
HSE: Temporary electrical suppliesHow can I practise this topic in 3D?

A damaged inspection-lamp cable

A cable defect is reported after a vehicle crossing
All related inspection points 4 across 2 locations
Garage workshop 2 inspection points
Construction site 2 inspection points
Practice in the SHAREhub environment. Browser practice is separate from workplace competence and formal learning records.
What is portable electrical equipment?
Portable electrical equipment is work equipment connected to an electrical supply by a plug and flexible cable and moved or handled during use or between uses.
The risk profile varies enormously. A laptop power supply in a dry office is not the same as a 230 V pressure washer used outdoors, an angle grinder on a construction site, a floor polisher used by a cleaning contractor, a catering extension lead, or a battery charger in a workshop. HSG107 is important because it moves the topic away from automatic annual testing and towards risk-based maintenance.
The main hazards are electric shock, burns, arcing, fire, trip hazards, equipment failure and secondary injury. Damage often occurs to plugs, flexible cables, strain relief, casing, switches, extension leads and equipment used in wet, dusty, hot, abrasive or outdoor environments.
Good management is a system: select suitable equipment, provide safe supply, train users, carry out user checks, complete formal visual inspections, test where justified, keep records proportionate, quarantine defects and review frequencies after damage or incidents.
| Topic | What it means | Management implication |
|---|---|---|
| Portable equipment | Equipment moved or handled and connected by plug and cable. | Likely to suffer damage, so needs checks and maintenance. |
| Transportable equipment | Equipment moved between locations but not necessarily hand-held during use. | Assess travel, set-up, cable route and supply. |
| User check | Simple pre-use look and feel check by the user. | Find obvious damage before use. |
| Formal visual inspection | Recorded inspection by a competent person. | Find damage users may miss. |
| Combined inspection and test | Electrical tests plus inspection where risk justifies it. | Use risk-based intervals, not automatic annual PAT. |
| RCD | Residual current device that disconnects supply quickly after some faults. | Useful additional protection, not a substitute for safe equipment. |
Inspection/test records and labels are useful management evidence, but there is no automatic standalone legal requirement to record every PAT activity or attach a sticker. Other applicable inspection duties may require records. Evidence should support the maintenance decision, not replace a present-condition check.
How can the hierarchy of controls prevent electric shock, burns and fire from portable equipment?
Consider a contractor using a 230 V portable grinder in a damp loading area. A crushed lead or failed insulation can put live parts within reach, while water and metalwork increase the chance and consequence of contact. Eliminate, Reduce, Isolate, Control, personal protective equipment (PPE) and Discipline (ERICPD) prompts decisions alongside the five-level hierarchy: elimination, substitution, engineering, administrative controls and PPE. The equipment type, supply and manufacturer instructions must be checked before choosing a method.
Eliminate: the project lead first asks whether the cutting can be completed off-site or by a pre-cut component. Check dimensions and installation tolerances before procurement; a site change that creates extra cutting defeats the choice. If the task can be removed, record the design decision and omit the exposed electrical work.
Substitute and reduce: if cutting remains, assess a suitable lower-voltage or battery tool for the material, runtime and environment. A battery removes a trailing mains lead but brings charging, thermal and mechanical risks; the purchaser verifies the product rating and actual cutting performance. Do not assume a voltage category or a test sticker proves the tool suitable.
Isolate and engineer: route leads away from traffic and water, protect connectors and use supply protection selected by a competent electrical person. An appropriately selected residual current device can reduce the consequence of some faults but is secondary protection, not permission to use damaged equipment. The user checks cable, plug, casing and connectors before each use; the competent maintainer inspects and tests at risk-based intervals. A damaged lead, exposed conductor, wet connector or repeated trip means disconnect, quarantine and investigate before repair and return.
Control, PPE and Discipline: brief users on checks, keep a defect route and authorise repairs and testing to people with the required competence. Supervisors sample actual use and review faults rather than relying on annual stickers. Gloves or footwear may be needed for other task hazards but are not a substitute for safe electrical design. Record the cause of damage, repair/test outcome and change to the maintenance interval.
Direct source: HSE portable appliance testing FAQ
Direct source: HSE work using electrically powered equipment
Direct source: HSE hierarchy of controls
What is the portable equipment maintenance hierarchy?
A good maintenance system has three layers: user checks, formal visual inspection and combined inspection and testing where risk justifies it.
The most valuable shift is from sticker culture to maintenance culture. Many dangerous defects are found by looking: a cracked plug, crushed cable, loose cord grip, overheating, taped repair, missing casing screw, water damage or extension lead overload. Testing has value, but it cannot replace daily awareness and defect control. See HSE portable appliance testing FAQ.
The three layers should be matched to the equipment and environment. A frequently moved tool in a harsh site environment needs far more attention than a static office monitor. The programme should also respond to evidence: if a type of equipment keeps failing, the answer may be better procurement, storage, routing, supervision or user training, not simply more frequent testing.
| Layer | Who usually does it | What it should achieve |
|---|---|---|
| User check | The person about to use the equipment. | Find obvious damage before energising equipment and stop unsafe use immediately. |
| Formal visual inspection | A trained competent person. | Check plug, cable, casing, strain relief, environment, suitability and visible defects more systematically. |
| Combined inspection and testing | A competent tester with suitable equipment and knowledge. | Detect faults not visible from inspection alone, such as earth continuity or insulation problems. |
| Repair/retest | Competent repairer/tester. | Confirm repaired equipment is safe before return to service. |
| Review of findings | Dutyholder, facilities or HSE lead. | Adjust frequencies and controls using defect patterns and incident learning. |
Which level of check is needed?
A practical decision tool helps decide whether a user check, formal visual inspection, combined inspection and test, specialist repair or removal from use is needed.
The decision should start with the work situation, not the calendar. A kettle in a staff kitchen, a charger in an office, a wet vacuum used by cleaners, a grinder on a site and a temporary event cable all have different likelihood of damage and different consequences if they fail. The check regime should reflect that difference.
The strongest systems also recognise stop triggers. If equipment is damaged, smells hot, trips protection devices, has exposed conductors, has been wet when not designed for it, or has been repaired informally, it should be removed from use until a competent person decides what happens next.
| Work situation | User check | Formal visual inspection | Combined inspection and test / specialist action |
|---|---|---|---|
| Low-risk office IT equipment | Look for obvious cable, plug or charger damage during use. | Periodic visual inspection where equipment is moved, shared or damage is likely. | Often not needed routinely unless risk changes, damage occurs or manufacturer/safety decision requires it. |
| Staff kitchen appliances | Check plug, cable, heat damage, water exposure and safe placement. | Regular visual inspection because heat, liquids and movement increase risk. | Test where inspection history, use or repair justifies it. |
| Workshop tools | Pre-use check by trained user every time. | Frequent formal inspection due to vibration, dust, oil and mechanical damage. | Periodic testing and post-repair testing by competent person. |
| Construction tools and leads | Daily or pre-use checks with clear stop rules. | High-frequency inspection matched to site conditions. | Testing programme based on HSG107-style risk, site environment, repairs and defect history. |
| Cleaning equipment | Check cable strain, wet exposure, plug, wheels and route before use. | Regular inspection because cables are dragged, wound and used around water. | Testing where wet use, movement or damage history creates uncertainty. |
| Hired/event equipment | Check condition before issue, installation and use. | Inspect at receipt, before deployment and after transport. | Test before hire/issue where required by risk, contract or repair status. |
| Damaged, wet or overheating equipment | Do not use. | Quarantine and label pending competent review. | Repair/retest or dispose; investigate if similar defects repeat. |
Illustrative low-risk IT decision: identify whether the device is Class I (protective earthing) or Class II (double insulation), and assess its detachable lead/charger separately. Record movement, environment, damage history and manufacturer constraints before selecting a maintenance regime. HSG107 distinguishes rarely moved double-insulated IT from earthed equipment; its starting intervals are advisory, not law. Review after damage or a changed use pattern. HSE HSG107 equipment maintenance
Completed illustrative record — office PC IT-024. Class I earthed desktop, rarely moved in a clean dry office; protected dedicated detachable lead assessed separately; no damage history and manufacturer instructions checked. The competent maintenance owner chooses formal visual inspection initially at two years and combined inspection/testing initially at five years, within HSG107’s advisory low-risk-IT starting range. These are this example’s assessed starting intervals, not legal deadlines or a rule for all IT. If the PC were Class II, the same table does not suggest routine combined testing; its lead/charger and use still need assessment. At the two-year review, no faults are found and the use is unchanged: keep the chosen regime with an earlier review after relocation, damage or changed conditions. A damaged lead triggers safe stop and competent assessment immediately, not waiting for the calendar.
What determines inspection and testing frequency?
Frequency should be based on equipment type, environment, use, movement, damage history and user competence.
The most important shift for learners is this: there is no legal requirement for every portable appliance to be tested every year. The legal requirement is maintenance to prevent danger. HSG107 explains a sensible system of user checks, formal visual inspection and testing based on risk.
A low-risk office printer may need little more than user awareness and infrequent inspection. A construction grinder, 110 V transformer, extension lead, site light or pressure washer used in wet or abrasive environments may need frequent checks and closer formal inspection. The system should learn from findings. If defects are common, frequency, procurement, storage, supervision or user training may need improvement.
| Risk factor | Lower risk example | Higher risk example |
|---|---|---|
| Environment | Dry office. | Wet, dusty, outdoor, corrosive or construction environment. |
| Movement | Desktop monitor rarely moved. | Extension lead moved daily between areas. |
| Mechanical damage | Protected cable route. | Cable dragged over sharp edges or through doors. |
| Voltage and supply | Low-risk IT equipment. | 230 V equipment outdoors or harsh use. |
| User type | Trained worker with defect reporting culture. | Multiple casual users or visitors. |
| Defect history | Few defects over years. | Frequent plug, cable or casing damage. |
| Equipment criticality | Low-consequence office charger. | Tool used in wet work, confined or public area. |

How can electricity injure the body, and why can a small mark hide a serious incident?
Interactive anatomy · Electrical injury · Updated 2026-10-23
Electrical injury terms
A broad term for injury associated with electrical exposure.
An external current affecting the body.
Tissue injury caused by electrical heating.
Death from electric shock.
Health and Safety Executive: Electrical injuries · Health and Safety Executive: Selection and use of electric handlamps, PM38 · NHS: Burns and scaldsRead all anatomy and process explanations without the viewer
General occupational awareness of anatomy and incident mechanisms. A broad term for injury associated with electrical exposure. An external current affecting the body. Tissue injury caused by electrical heating. Death from electric shock. Electrical rescue, live testing, isolation or energised work instruction An energise-person control, contact timer, voltage or resistance input Safe current paths, survival percentages or shock-severity scores ECG interpretation, rhythm selection or AED shock decisions Medical or workplace clearance from a mark, diagram or feeling well The hazard-avoidance and medical-help panel is visible before model loading and quiz completion.
Nerve pathway
Nerves communicate using electrical and chemical signals. Nerves carry biological signals, and communication at the nerve-to-muscle connection helps activate muscle. The travelling cue is a simplified way of directing attention to that relationship. It does not show household current circulating through a person, and its colour, speed or brightness cannot be used to interpret nerve function or electrical injury. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling · Oxford University Hospitals NHS Foundation Trust: Nerve Conduction Studies and Electromyography
Skeletal muscle
The nervous system normally coordinates muscle contraction. A slow hand movement demonstrates normal function; it does not imitate a casualty’s involuntary movements. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling
Breathing muscles
Coordinated muscle activity helps move air into and out of the lungs. The diaphragm and chest movement belong to the respiratory lesson. This example shows no breathing-rate measurement. Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role
Heart conduction
Coordinated electrical activity helps organise the heart’s pumping. A labelled sequence illustrates normal biological activation. It is not an ECG or a rhythm-interpretation exercise. St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system · NHS 111 Wales: Cardiac Arrest
Skin contact region
Contact conditions influence how an electrical exposure affects the body. The marker identifies an example contact region. It does not calculate skin resistance or identify a safe point to touch. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Internal tissue region
Electrical injury can extend beneath the visible surface. An electrical incident can cause effects below the surface, so visible appearance alone cannot describe the whole injury. This transparent region marks the subject of the explanation, rather than a measured boundary of damage. Its shape does not establish where current travelled or which tissues are unaffected; compare it with the selected mechanism caption. Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns
External source
The incident hazard comes from an electrical source outside the body. The generic equipment symbol is kept disconnected from the normal biological signalling diagram. Health and Safety Executive: Introduction to electrical safety
Illustrative exposure route
This broad region represents one possible exposure route. It cannot establish the actual route or outcome. There is no safe-path selector, voltage control or timed-contact exercise. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Arc and thermal region
An arc or hot electrical equipment can cause injury. This separate incident panel is different from a simple through-body current diagram. No arc flash is animated. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
Secondary injury
Loss of control can lead to falls or contact with nearby hazards. The neutral surrounding-hazard symbol recognises these injuries without staging a fall or body jerk. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
Response boundary
Keep clear of unresolved electrical danger and get emergency help. Do not touch a person who may still be in contact with an electrical source. This node opens the safety panel, never a rescue activity. Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electricity — electric shock and overhead-line precautions · Health and Safety Executive: Emergency procedures
Open the complete process transcript
The process, step by step
Explore normal function
Start with the body’s own signalling: nerves communicate with muscles, breathing muscles move the chest, and organised activation coordinates the heart. Select one example at a time and read the associated label before changing systems. These are normal biological functions, not electricity from equipment moving through a person. The slow cues make the explanation easier to follow; they do not show a measured nerve signal, breathing rate or heart rhythm. This process sequence is a teaching route through the subject, not a simulation of an electrical accident. Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function · NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling · Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role · St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system
What to watch: Select the nerve, skeletal-muscle, breathing-muscle and heart labels individually, noticing that each belongs to a different normal biological example.
Why it matters: Normal signalling helps muscles work in a coordinated way. Keeping these biological examples distinct from the incident diagrams makes it easier to explain what an external electrical hazard can disrupt.
Explore this step: Explore one normal system, then explain its function before selecting a different system.
Locate the external hazard
Locate the generic electrical-source symbol outside the body and compare it with the normal biological labels. It represents an external workplace hazard, not the source of ordinary nerve or heart signalling. The model keeps the equipment symbol separate and does not energise the silhouette when a learner selects it. This step establishes the context before the different injury mechanisms are discussed. A picture of equipment cannot show whether real equipment is safe. Use the label to identify the distinction, rather than imagining that the model is testing a circuit. Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Emergency procedures
What to watch: Locate the external-source symbol and the response-boundary label, then compare their positions with the normal body-system labels.
Why it matters: An external electrical supply is a hazard that requires competent control. Separating it from biological signalling avoids implying that a normal nerve pathway describes a safe route for electrical current.
Explore this step: Identify which labels describe the body and which identify the external hazard or safety boundary.
Choose an incident example
Choose one incident explanation: electric shock, electrical heating within tissue, or an arc and its thermal effects. These are different mechanisms and more than one may be relevant to an incident. Read the selected heading before examining the highlighted region so that the image and explanation remain connected. The model is a route through the concepts, not a calculation of current flow or injury severity. It provides no voltage control, safe-contact experiment or animated arc. Compare the labels to explain how the mechanisms differ without ranking an actual casualty’s injuries. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety
What to watch: Read the incident heading, then locate its contact, internal-tissue or arc-and-thermal label rather than combining every marker into one route.
Why it matters: Shock can disturb body function, while heating can injure tissue. An arc can cause thermal injury without being equivalent to the simple contact diagram; the examples can overlap in a real incident.
Explore this step: Compare two incident panels and describe the different mechanism named by each heading.
Explain possible effects
Read the caption beside the selected system and trace the labelled relationship being explained. Electric shock can interfere with muscle control, breathing or the way the heart beats; electrical heating can damage tissue. The highlighted region is a teaching focus, not a map of an individual’s injury. It cannot identify the actual route through the body or declare that an unhighlighted organ is unaffected. Compare the normal-function labels with the incident caption, keeping the possible effect separate from any claim about what has happened to a particular person. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
What to watch: Compare the breathing-muscle, heart and internal-tissue labels with the caption for the incident mechanism currently selected.
Why it matters: Interference with coordinated muscle or heart function can be serious even when an illustration shows little surface change. A teaching marker cannot determine which effects are present or absent in a real person.
Explore this step: Choose a system and describe its normal role before reading the possible effect in the incident caption.
Know the limits
Finish by comparing the questions the diagram answers with those it cannot answer. It can introduce normal signalling and distinguish several possible injury mechanisms. It cannot establish an actual exposure, the extent of damage, a safe electrical condition or medical clearance. A small-looking electrical burn or feeling well does not provide that clearance. The external-source and response-boundary labels keep these limits visible. Review them alongside the existing safety panel; completing this teaching route is not a rescue procedure, a clinical assessment or permission to resume the work. NHS: Burns and scalds · Health and Safety Executive: Electrical safety frequently asked questions · NHS 111 Wales: Burns and scalds — electrical burns
What to watch: Locate the internal-tissue and response-boundary labels, then compare the limits stated in their captions with the incident explanation.
Why it matters: Visible appearance alone cannot establish the seriousness of electrical injury. Keeping the model’s scope clear prevents an explanatory picture or completed activity being mistaken for evidence that a person or workplace is safe.
Explore this step: Name one question the model explains and one question that requires assessment beyond this teaching view.
Mechanisms and their limits
Electric shock: disruption of normal function External electrical current can interfere with muscle control, breathing or the heart’s organised activity. These are possible effects; the same diagram cannot predict the outcome of a real incident. An illustrative route does not show that a particular organ must or cannot be affected. No arbitrary arrhythmia, dramatic flatline, body jerk or calculated survival result is shown. Both alternating and direct current can be dangerous. The viewer offers no safe voltage or safe path. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
HSE: prevent electrical injury
Electrical heating: injury beneath the surface Current passing through tissues can generate heat and cause burns beneath the skin. A small visible mark is not enough to judge the internal effects. Not every shock produces extensive burns. The marked region is illustrative, not a reconstructed path, calculated burn depth or severity score. An electrical burn needs emergency medical assessment even if it appears small. Feeling well or selecting a similar image does not provide workplace or medical clearance. Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns
NHS: electrical burns need emergency care
HSE: electrical injury mechanisms
Electric shock: disruption of normal function — follow the anatomy
Look at: The contact route through the body, including nerves and muscle.
What changes: Electric current can interfere with normal nerve, muscle, breathing or heart activity.
Why it matters: A person may be unable to let go, collapse or develop a dangerous rhythm.
What to do: Keep clear, do not touch anyone still in contact with electricity, call 999 and follow competent site emergency arrangements.
Damaged portable equipment presents an unresolved electrical hazard
A worker finds damaged equipment near a damp work area; the exposure is a counterfactual failure of controls, not a rescue exercise. An acute incident is explained in 32 seconds without voltage, current or contact-duration inputs. The sequence sets no safe exposure or waiting time. Never touch a person or equipment while electrical danger is unresolved. The viewer cannot prove isolation or infer the actual current path or outcome.
Keep clear of the unresolved source Damaged equipment in a damp area is a stop-and-report situation. Do not touch a potentially live casualty; call appropriate help and use competent site emergency arrangements. Health and Safety Executive: Electrical safety frequently asked questions · Health and Safety Executive: Emergency procedures
What failed barriers could allow The counterfactual contact example marks an external source and possible exposure. It does not ask the learner to energise a person or select a supposedly safe route. Health and Safety Executive: Electrical injuries · Health and Safety Executive: Electrical safety frequently asked questions
Possible interference with normal function External current can affect muscle control, breathing or heart function. These are possible effects, not a prediction that every organ is involved or that a particular contact is survivable. Health and Safety Executive: Electrical injuries
Safety first, then urgent assessment Keep clear and obtain emergency help while danger remains. Only once the scene is safe does the separate unresponsive/abnormal-breathing CPR/AED guidance apply. Feeling well does not provide medical or equipment clearance. Health and Safety Executive: Electrical safety frequently asked questions · NHS: Burns and scalds · NHS 111 Wales: Cardiac Arrest · Health and Safety Executive: Emergency procedures
Electrical heating: injury beneath the surface — follow the anatomy
Look at: The tissue beneath the electrical contact points.
What changes: Current can generate heat inside the body as well as at the skin.
Why it matters: A small visible mark can conceal serious deeper injury.
What to do: Keep the scene safe; electrical burns need 999 or A&E assessment even when the visible mark is small.
A small external mark after an electrical incident
After an electrical incident, a worker has a small visible hand mark; the area must be made safe by competent arrangements. This is a possible injury explanation, not a burn-depth model or a simulation of tissue heating at a selected exposure time. Visible marks cannot establish the route or depth of internal injury. Not every shock produces the broad affected area used in this illustration.
Do not approach unresolved energy danger The incident is treated as an electrical emergency until the scene is safe. Keep clear, summon appropriate help and do not judge safety from a small mark. Health and Safety Executive: Electrical safety frequently asked questions · NHS: Burns and scalds
External current can heat tissues A broad translucent region represents possible tissue heating during contact. It is not a wire tracing the real route and it does not calculate dose from a contact point. Health and Safety Executive: Electrical injuries
An external mark may understate injury The selected region separates possible internal effects from the skin marker. Size or appearance of the mark cannot clear the person or tell the learner what tissues were actually injured. Health and Safety Executive: Electrical injuries · NHS 111 Wales: Burns and scalds — electrical burns
Arrange medical assessment Use emergency help for electrical burns and follow live advice once it is safe to assist. Do not continue work or reassure someone simply because the mark is small; the activity gives no treatment or return-to-work clearance. NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burns · Health and Safety Executive: Emergency procedures
Read the practice situations and all answer explanations
EL-Q1: What can be concluded from the mark?
A colleague has had an electrical incident and has only a small visible mark.
It proves the event was harmless. — A small mark cannot rule out internal effects. Electrical burns need emergency care.
Internal effects cannot be judged from the mark; seek appropriate medical assessment. — Correct. Do not use appearance as reassurance. Keep the area safe and obtain appropriate medical help; an electrical burn requires 999 or A&E.
Select the closest route in the model to calculate survival. — The model cannot reconstruct the incident or predict survival. Seek appropriate help instead of matching an image.
Health and Safety Executive: Electrical injuries · NHS: Burns and scalds · NHS 111 Wales: Burns and scalds — electrical burnsEL-Q2: Which response avoids creating another casualty?
Someone may still be in contact with a live electrical source.
Touch them immediately to pull them away. — Do not touch them while the electrical danger is unresolved. You could also be injured. Call for emergency help.
Keep clear, call emergency help and follow competent site emergency arrangements. — Correct. Call 999 and explain that electricity is involved. Keep others clear and follow competent emergency arrangements; this lesson does not teach electrical rescue or isolation.
Use the viewer to find the safest current path. — There is no safe-path or rescue method in this viewer. Keep clear and get emergency help.
Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electricity — electric shock and overhead-line precautions · Health and Safety Executive: Emergency proceduresEL-Q3: What still needs consideration?
An arc incident happens without an obvious hand-to-foot contact route.
There cannot be an injury without that route. — A simple through-body route is not required for an arc/thermal injury or a secondary fall.
Arc, heat and secondary injuries. — Yes. Consider the incident hazards and obtain appropriate help rather than forcing the event into one current-path drawing.
Direct-current equipment cannot cause harm. — Both AC and DC equipment can be hazardous. Neither label provides reassurance.
Health and Safety Executive: Electrical injuries · Health and Safety Executive: Introduction to electrical safety · Health and Safety Executive: Electrical safety frequently asked questionsSources and how the model is made
The opening images are AI-generated anatomical illustrations. The interactive 3D models and labelled SVG diagrams use original procedural artwork. These teaching images are not medical scans or diagnostic tools. Source references support the learner explanations and do not grant artwork rights.
- Health and Safety Executive: Electrical injuries — Possible shock effects, deep tissue heating, loss of muscle control, thermal and secondary injuries; AC and DC hazards. No numerical voltage/contact-time thresholds transferred.
- Health and Safety Executive: Introduction to electrical safety — Contact, arcing, fire/explosion and secondary falls; suitable equipment and competent maintenance/assessment. No isolation or live-work procedure generated.
- Health and Safety Executive: Selection and use of electric handlamps, PM38 — Page 1 defines electrocution as death from electric shock; replaces the brief’s US terminology source. No equipment specification or voltage rule copied into this awareness lesson.
- NHS: Burns and scalds — Current page reviewed 31 March 2026: electrical burns require 999 or A&E. No chemical-skin or eye-irrigation timer substituted.
- Alder Hey Children’s NHS Foundation Trust: Nerve service — normal nerve function — Basic biological electrical signalling and motor/sensory roles only. No paediatric injury prognosis or treatment transferred to the occupational module.
- NHS: Lambert-Eaton myasthenic syndrome — normal nerve-to-muscle signalling — Normal nerve signalling followed by chemical communication to activate muscle. Disease mechanisms and treatment are outside this module.
- Oxford University Hospitals NHS Foundation Trust: Nerve Conduction Studies and Electromyography — Natural electrical signals in nerves and muscle activity. No diagnostic procedure, test voltage or stimulation activity reused.
- Cambridge University Hospitals NHS Foundation Trust: Breathing pattern disorders and physiotherapy — normal diaphragm role — Diaphragm movement and air movement during breathing only. No exercise programme, self-assessment or rate target reused.
- St George’s University Hospitals NHS Foundation Trust: Catheter Ablation for Supra-Ventricular Tachycardia — normal electrical system — Page 2 normal cardiac electrical activation coordinating contraction. Printed review date October 2026 needs recheck at sign-off. No clinical procedure, ECG or third-party artwork copied.
- Health and Safety Executive: Electrical safety frequently asked questions — AC/DC hazards, multifactorial outcome uncertainty and need for competent safety assessment. No safe-voltage, resistance, RCD guarantee or risk score imported.
- NHS 111 Wales: Burns and scalds — electrical burns — A small-looking electrical burn can be very damaging and needs immediate medical attention. No household separation/rescue procedure copied.
- NHS 111 Wales: Cardiac Arrest — Unresponsive and absent/abnormal breathing, gasping, immediate 999/CPR/call-handler/AED recognition pathway. Applies only after electrical danger is resolved. No clinical ECG decision or full CPR course.
- Health and Safety Executive: Electricity — electric shock and overhead-line precautions — Do not touch a casualty while electrical danger remains; stay clear and warn others; first aid requires training. No separation technique, escape manoeuvre or rescue distance imported.
- Health and Safety Executive: Emergency procedures — Competent emergency control, calling emergency services, site arrangements and no resumption while serious danger remains. No procedural isolation instruction generated.
How should inspection and testing intervals be decided?
Inspection and testing intervals should be justified by risk factors and then adjusted when evidence shows equipment is degrading faster or slower than expected.
An office laptop left on one desk has a different damage history from a site grinder passed between shifts. Start with environment, movement, users and defect records; the equipment owner then chooses a user-check and inspection plan and changes it if defects appear. A test date alone cannot determine the next safe interval. GB source: HSE portable appliance testing FAQ
| Equipment situation | User check | Formal visual inspection and testing logic |
|---|---|---|
| Static office IT equipment | User awareness and report obvious damage. | Formal visual inspection may be infrequent; combined testing often not needed unless risk changes. |
| Office kitchen appliances | Check plug, cable, heat damage and cleanliness before use. | More frequent visual inspection because heat, water and movement increase damage potential. |
| Cleaning equipment | Check cable, plug, strain relief, water exposure and trip routing before each use. | Regular formal inspection; testing where movement/wet use/damage history justify it. |
| Workshop hand tools | Pre-use check by trained user. | Frequent inspection and periodic testing based on use, vibration, dust, oil and damage history. |
| Construction tools and leads | Daily/pre-use check expected. | High-frequency inspection and testing regime informed by HSG107 and site conditions. |
| Hired tools | Check on issue and before use. | Inspection and testing before hire/issue, with hirer controls during use. |
| Repaired or suspected damaged equipment | Do not use until cleared. | Inspect and test before return to service. |
What should user checks and visual inspections look for?
User checks should find obvious damage before use; formal visual inspections should examine equipment more deliberately and record defects.
Before plugging in, the user looks for a cracked plug, damaged lead, heat marks or an unsuitable socket and removes suspect equipment from use. A competent formal visual inspection can find faults the quick check misses; testing is chosen where the risk and inspection findings justify it. Record who isolated the item and what evidence allows its return. GB source: HSE HSG107 - Maintaining portable electrical equipment
| Check item | User check | Formal visual inspection |
|---|---|---|
| Plug | Cracked, burnt, loose or damaged plug. | Correct fuse, wiring, pins, casing and strain relief where accessible/appropriate. |
| Cable | Cuts, abrasion, crushed cable, exposed conductors or taped repairs. | Cable type, length, condition, anchorage and suitability. |
| Equipment casing | Cracks, missing parts, burn marks or loose components. | Integrity, labels, switches, guards and environmental suitability. |
| Extension leads | Damage, overheating, overloaded reels or trailing-trip risks. | Rating, cable condition, sockets, thermal damage and use controls. |
| Environment | Wet floor, outdoor rain, dust, heat or sharp edges. | Supply suitability, RCD, IP rating and cable route. |
| Defects | Stop using and report. | Quarantine, repair by competent person or dispose. |
When is electrical testing needed?
Electrical testing is needed where inspection alone is not enough to confirm safety for the equipment, use and environment.
Testing can include earth continuity, insulation resistance, polarity and other checks appropriate to the class and type of equipment. But testing without inspection is weak because many dangerous faults are visible: damaged cables, cracked plugs, missing strain relief, signs of overheating or unsuitable use.
The term PAT testing is widely used, but it can mislead people into thinking the sticker is the control. The control is the full maintenance system. A valid test label on a damaged tool is not proof of safety. A competent programme should specify who checks, who inspects, who tests, how often, what records are kept, what happens to defects and how frequencies are reviewed.
| Situation | Likely approach | Reason |
|---|---|---|
| Low-risk IT equipment in dry office | User awareness and infrequent formal visual inspection may be enough. | Damage likelihood is low. |
| Hand-held power tool in workshop | Frequent user checks, formal inspection and periodic testing. | Movement and mechanical damage are credible. |
| Construction site tool | Frequent checks and inspection; testing based on site risk and HSG107 guidance. | Harsh conditions and damage likelihood are high. |
| Extension lead used by many people | Regular visual inspection and testing where justified. | Cables and plugs are vulnerable. |
| Equipment after repair | Inspect and test before return to use. | Repair must restore electrical safety. |
| Equipment exposed to water/damage | Remove, inspect and test before reuse if safety uncertain. | Moisture and damage can create shock risk. |
What PAT testing myths should be challenged?
The main myth is that a yearly PAT sticker proves portable electrical equipment is safe.
A PAT label records a past check, not the condition of the lead after a new crush or spill. When damage is reported, isolate and inspect the item now rather than waiting for the next calendar test. Choose future inspection and testing intervals from use and defect history, not a blanket annual rule. GB source: HSE portable appliance testing FAQ
| Myth | Why it is wrong | Better practice |
|---|---|---|
| Everything must be PAT tested every year. | HSE guidance supports risk-based maintenance, not automatic annual testing. | Set intervals by equipment, environment, use and defect history. Source: HSE PAT FAQ |
| A valid sticker means the item is safe. | Equipment can be damaged after testing. | Use pre-use checks and remove damaged equipment immediately. |
| Testing is more important than visual inspection. | Many dangerous faults are visible. | Train users and inspectors to identify plug, cable, casing and overheating defects. |
| Only electricians can do visual inspections. | Formal visual inspection needs competence, not always full electrician qualification. | Define competence for each level of check. |
| RCDs make faulty equipment acceptable. | RCDs are additional protection and may not prevent all harm. | Use suitable, maintained equipment and safe supply. |
| Labels should drive the next test date. | Risk can change if equipment moves to a harsher environment. | Review intervals when use, location or condition changes. |
Why is annual PAT not a control strategy?
Annual PAT testing can be part of a risk-based maintenance system, but it is not a control strategy by itself.
A yearly test can only tell you about the condition of an item at the time it was inspected and tested. It does not stop a cable being crushed the next day, a charger overheating in a drawer, an extension reel being overloaded, or a construction tool being dropped and kept in use. Treating the label as the control creates false confidence. HSE confirms that the law does not set an annual PAT interval. See HSE portable appliance testing FAQ.
A proper control strategy includes suitable equipment selection, safe supply, user checks, formal visual inspection, testing where justified, defect quarantine, competent repair, storage, contractor control and trend review. The most important question is not 'is there a sticker?' but 'is this item safe for this task, in this place, today?'
| Question | Sticker-led answer | Risk-control answer |
|---|---|---|
| Is the item safe today? | It was tested this year. | The user has checked plug, cable, casing, environment and signs of overheating before use. |
| Is the equipment suitable? | It has a label. | Voltage, IP rating, duty, supply, RCD/transformer and environment have been considered. |
| What happens to defects? | Wait until next test. | Stop, label, quarantine, repair/retest or dispose immediately. |
| What does defect data show? | No one reviews it. | Defect trends change procurement, storage, routing, supervision and frequency. |
| How are contractors controlled? | They say their tools are PAT tested. | Tools are checked on entry and removed if unsuitable or damaged. |
How should portable electrical equipment be controlled?
Control starts with suitable equipment and safe supply before inspection and testing.
This section turns legal language into workplace control. The examples show how broad duties become risk assessment, competent help, consultation, maintenance and review evidence.
| Control layer | Practical example | Evidence |
|---|---|---|
| Eliminate the local cutting task / distinguish substitution | Use pre-cut components or avoid local cutting where feasible. Battery, lower-voltage or pneumatic alternatives are substitution choices for the assessed task; a battery may remove a trailing mains lead but leaves cutting, electrical/thermal and other risks. | Task design review. |
| Select suitable equipment | Correct voltage, IP rating, class, cable and duty rating. | Procurement specification. |
| Safe supply | Suitable sockets, transformers, RCDs and protected circuits. | Electrical installation/temporary supply record. |
| Protect from damage | Cable management, guards, routing and storage. | Workplace inspection. |
| User checks | Pre-use checks and defect reporting. | Briefing and observation. |
| Formal inspection/testing | Risk-based inspection and testing by competent people. | Register, inspection and test records. |
| Defect control | Quarantine, repair, retest or disposal. | Defect log and close-out. |
How does portable equipment risk differ by sector?
Sector context changes the likely damage, environment, user behaviour and inspection frequency.
A charger in a dry office may need awareness and occasional visual review, while a frequently moved construction tool faces impact, water and damaged temporary leads. Compare the real use with the sector example before setting a check frequency; an office interval should not be copied onto site equipment. GB source: HSE HSG107 - Maintaining portable electrical equipment
| Sector | Typical equipment | Risk focus |
|---|---|---|
| Office | Laptops, chargers, monitors, printers and extension blocks. | Trailing leads, damaged chargers and low-risk inspection. |
| Construction | Grinders, breakers, 110 V transformers, site lights and extension leads. | Harsh damage, wet conditions, temporary supply and daily checks. |
| Cleaning | Floor polishers, vacuums, pressure washers and extension leads. | Wet floors, cable damage and plug strain. |
| Hospitality | Kettles, mixers, heated equipment and temporary catering equipment. | Heat, water, cleaning chemicals and public interface. |
| Workshop | Drills, grinders, welders, chargers and portable lamps. | Mechanical damage, dust, metal swarf and flammable areas. |
| Education/leisure | Charging trolleys, AV equipment, portable PA and extension leads. | Multiple users, public areas and cable control. |
What extra controls matter on construction sites?
Construction sites need a higher control standard because portable equipment is exposed to impact, water, dust, sharp edges, temporary supplies and multiple users.
At a site, verify the supply, transformer or RCD arrangement, cable route, weather exposure and the tool before work starts. A reduced-voltage system or RCD can reduce a particular harm route, but it cannot make a cut cable or unsuitable tool safe. Stop and isolate a defective item, then verify the replacement and supply before handback. GB source: HSE work using electrically powered equipment
| Issue | Why it matters | Control expectation |
|---|---|---|
| 110 V centre-tapped systems | Reduced voltage can reduce electric shock severity in harsh environments. | Use site strategy for suitable voltage and transformers. |
| RCD protection | Useful for some supplies, especially where 230 V is used. | Use correctly rated RCDs and test as required; do not rely on RCDs alone. |
| Extension leads | Long leads can be damaged, overloaded, coiled or routed through water/traffic. | Use suitable rated leads, protect routes and avoid overloading or coiled heat build-up. |
| Temporary lighting | Lights and cables can be damaged or placed in wet/impact areas. | Use suitable IP rating, guarding, cable routing and inspection. |
| Contractor tools | Site may not know condition or test history. | Check at site entry and remove damaged or unsuitable items. |
| Charging batteries | Chargers can overheat or be used in unsuitable areas. | Use designated charging areas, compatible chargers and fire controls. |
| Wet cutting or outdoor work | Water and damaged cables increase shock risk. | Use suitable equipment, RCD/voltage strategy, routing and weather controls. |
How should batteries and chargers be controlled?
Battery-powered equipment can reduce cable and shock risks, but damaged chargers, lithium batteries and poor charging arrangements can create fire, burn and electrical risks.
Moving to cordless tools does not remove the need for electrical control. Chargers, batteries, extension leads, storage bags and charging locations become part of the risk assessment. Lithium batteries in particular should be protected from impact, heat, water, incompatible chargers and charging in escape routes or combustible storage areas.
HSE construction fire guidance identifies short circuits, damage, extreme temperature and over-charging of batteries in plant and tools as ignition risks. Apply the actual battery and charger instructions, and assess other workplaces for their own charging and fire conditions. See HSE HSG168 fire safety in construction.
A practical system sets rules for approved chargers, damaged battery quarantine, charging locations, overnight charging, fire detection or supervision where needed, separation from combustibles, and emergency action if a battery becomes hot, swollen, leaking, smoking or physically damaged.
| Issue | What can go wrong | Control standard |
|---|---|---|
| Incompatible charger | Wrong charger can overheat or damage battery. | Use manufacturer-approved chargers and procurement control. |
| Damaged battery | Dropped, crushed, swollen or leaking batteries can fail or ignite. | Quarantine and dispose through competent route; do not recharge. |
| Poor charging location | Fire can spread to combustibles or block escape routes. | Designated charging area away from exits, waste and flammable storage. |
| Overnight/unattended charging | Failure may go unnoticed. | Risk-assess need, supervision, detection, isolation and manufacturer instructions. |
| Wet or dusty charging | Electrical and fire risk increases. | Keep chargers dry, ventilated and protected. |
| Mixed ownership | Personal or contractor chargers introduced uncontrolled. | Approved equipment rules and site-entry checks. |
| Emergency response | Workers may handle a failing battery incorrectly. | Brief stop-use, isolation, evacuation and fire-response arrangements. |
A cool damaged battery awaiting a planned safe disposal route differs from a hot, smoking or failing battery. For the latter, use the site’s emergency/evacuation response and keep people away; an ordinary user should not carry it to a quarantine box.
Why is annual PAT testing alone not enough?
A worked example shows why the maintenance system matters more than the sticker.
A construction contractor has all tools tested every January. In March, an angle grinder is dropped, the cable is damaged, and the plug is pulled by the cable each day. The tool still has a valid test sticker, so workers keep using it. The weakness is not the test; it is the absence of user checks, defect reporting, supervision and quarantine.
The competent response is to train users on pre-use checks, inspect high-risk tools frequently, quarantine damaged equipment immediately, repair or dispose through a competent route, review storage and cable routing, and use defect trends to improve procurement and supervision.
| Stage | Weak approach | Better approach |
|---|---|---|
| Inspection plan | Annual PAT for all equipment. | Risk-based inspection and testing by equipment and environment. |
| User checks | No pre-use check. | Brief users to check cable, plug, casing and environment. |
| Damage | Tool kept in use because sticker is valid. | Stop, label, quarantine and report. |
| Repair | Informal taped cable repair. | Competent repair and retest before use. |
| Learning | No trend review. | Review defect patterns, storage, procurement and supervision. |
Operational example and hold points
Task material and setting: Cleaning contractor uses a mains floor polisher at a wet entrance; supply, rating and cable route matter.
People and prerequisites: User, supervisor, competent electrical maintainer and nearby pedestrians; product information and suitable supply are available.
Before: Confirm suitability, route lead away from water and traffic, check plug/casing/lead and inspection history.
During: Keep lead dry and protected, watch for damage or protective-device trips, keep others clear.
Hold or stop: Crushed or exposed cable, wet connection or repeated trip; disconnect and quarantine.
Completion and hand back: Competent repair/inspection/test where needed, then supervisor releases the machine for use.
Evidence: Equipment specification, risk assessment, user check, defect quarantine, repair/test and return-to-use decision.
What evidence shows portable equipment is controlled?
Evidence should show risk-based maintenance, not just a folder of test labels.
Evidence should be read as a chain rather than a filing exercise. A single record rarely proves good management on its own; stronger assurance comes from matching records, observations, interviews, trends and verified action closure.
| Evidence | What good looks like | Weakness to challenge |
|---|---|---|
| Equipment register | High-risk equipment, locations and inspection frequency captured. | List not updated after purchases. |
| Risk basis | Frequency based on environment, use and damage history. | Same annual interval for everything. |
| User check training | Users know what to check and when to stop. | Users rely on sticker only. |
| Inspection/test records | Competent checks and tests recorded proportionately. | Records exist but no defect action. |
| Defect quarantine | Damaged items removed, labelled and controlled. | Defective items left in stores. |
| Contractor control | Contractor equipment checked before use on site. | Contractor tools assumed safe. |
| Trend review | Defect patterns inform purchasing and supervision. | Same cable damage repeats. |
Which legal duties apply to portable electrical equipment?
Portable electrical equipment is controlled through electrical safety, PUWER, risk assessment and safe-system duties.
The rows distinguish Great Britain and Northern Ireland. Choose the instrument for the work location and the actual equipment or task; a guidance page or voluntary standard does not replace legal text.
| Duty or regulation | What it requires | How to apply it |
|---|---|---|
| Health and Safety at Work etc. Act 1974 | Requires safe systems, safe plant and protection of workers and others. | Manage portable equipment so it does not create shock, burn, arc or fire risk. |
| Electricity at Work Regulations 1989 | Requires electrical systems to be constructed, maintained and used to prevent danger. | Use risk-based inspection, testing, maintenance and defect control. |
| Management of Health and Safety at Work Regulations 1999 | Requires assessment, preventive arrangements, competence and review. | Set inspection frequencies from risk rather than default annual PAT testing. |
| Provision and Use of Work Equipment Regulations 1998 | Requires work equipment to be maintained in an efficient state, in efficient working order and in good repair. | Use maintenance records, defect quarantine and user checks. |
| Construction (Design and Management) Regulations 2015 | Requires construction work to be planned, managed, monitored and coordinated. | Control 110 V tools, site transformers, temporary supplies, harsh environments and contractors. |
| DSEAR 2002 | Requires ignition sources to be controlled around dangerous substances. | Do not use unsuitable electrical equipment in flammable or explosive atmospheres. |
| Electricity at Work Regulations (Northern Ireland) 1991 | Maintain electrical systems and equipment to prevent danger. | Use the Northern Ireland instrument for the worksite and assess the actual equipment, supply and environment. |
| Health and Safety at Work (Northern Ireland) Order 1978 | Protect employees and others from work risks. | Plan safe use, maintenance and supervision of portable equipment. |
| Provision and Use of Work Equipment Regulations (Northern Ireland) 1999 | Requires suitable work equipment, safe maintenance and appropriate inspection. | Use the NI work-equipment instrument alongside NI electrical duties for portable tools and cleaners. |
The Great Britain Electricity at Work Regulations require equipment to be maintained to prevent danger; they do not prescribe an annual portable appliance test. Source: HSE portable appliance testing FAQ
How should the control be managed and reviewed?
For a GB workplace, HSE guidance supports identifying the actual risk, taking practical protective steps and reviewing whether they work. Name the decision owner, check the control during the real task and correct a failed arrangement. Apply the separate Northern Ireland duties and guidance where the work is in NI.
GB management guidance: HSE managing health and safety
What training and competence helps?
Training should make users able to spot damage, stop use and understand why a sticker is not enough.
Training should be role-based. General awareness creates a baseline, but supervisors, managers, advisers and senior leaders need different levels of decision-making, verification and escalation competence.
| Role | Demonstration | Assessor | Record and reassessment |
|---|---|---|---|
| Users and nearby staff | Find visible cable, plug and casing faults and know how to disconnect and report. | Supervisor observes a real pre-use check. | Briefing and fault route; repeat after a near miss or equipment change. |
| Inspectors and testers | Distinguish visual from electrical faults; select the correct test for equipment class and manufacturer limits. | Competent electrical lead witnesses inspection and interpretation. | Inspection/test result and scope of authorisation; revisit after errors or new equipment. |
| Supervisors and hire coordinators | Select equipment for the environment, quarantine faults and check return after repair or hire. | Manager samples a damaged-tool scenario. | Issue/return and corrective-action record. |
| Managers and advisers | Set risk-based intervals from fault history, use and environment; audit the maintenance system. | Competent reviewer samples equipment, records and work conditions. | Maintenance rationale and interval review after changing risk. |
What do the acronyms and key terms mean?
Acronyms should be understood before they are used in assessments, briefings, audits or learning answers.
Acronyms can exclude newer readers if they are not explained. This section keeps the main terms available at the end of the page so the article stays readable while still supporting learners and audit users.
| Acronym | Meaning | Plain-English use |
|---|---|---|
| EAWR | Electricity at Work Regulations | UK electrical safety regulations. |
| PUWER | Provision and Use of Work Equipment Regulations | UK work equipment regulations. |
| PAT | Portable Appliance Testing | Common term for inspection and testing of portable electrical equipment. |
| RCD | Residual Current Device | Device that disconnects supply after certain earth faults. |
| SELV | Separated or Safety Extra Low Voltage | Low-voltage system used to reduce shock risk in some contexts. |
| IP | Ingress Protection | Rating showing protection against solids and liquids. |



Unlock another resource
You have used this month’s two free downloads. Publish a post in your own words to unlock one more resource, or choose SHARE Individual for 10 downloads per month.
You decide whether to share. If you do, use the relevant platform disclosure tools and do not make claims you do not genuinely hold.